Remote jack (CI-V) information
Controller to IC-7600
FE FE 7A E0 Cn Sc Data area FD
Preamble
code (fixed)
Transceiver’s
default address
Controller’s
default address
Command number
(see the command table)
Sub command number
(see command table)
BCD code data such as
for frequency, memory
number entry
(see data content description)
End of message
code (fixed)
OK message to controller
FE FE E0 7A FB FD
FE FE E0 7A FA FD
Preamble
code
(fixed)
Controller’s
default address
Transceiver’s
default address
OK code
(fixed)
End of message
code (fixed)
NG message to controller
NG code
(fixed)
IC-7600 to controller
q w e r t y u
FE FE E0 7A Cn Sc Data area FD
q w e r t y u
12
151
CONTROL COMMAND
D CI-V connection example
The transceiver can be connected an optional CT-
17 ci-v level converter to a PC equipped with an
RS-232C port. The Icom Communications Interface-V
(CI-V) controls the transceiver.
Up to 4 Icom CI-V transceivers or receivers can be
connected to a PC equipped with an RS-232C port.
See p. 134 for setting the CI-V condition using set
mode.
D Data format
The CI-V system can be operated using the follow-
ing data formats. Data formats differ according to
command numbers. A data area or sub command is
added for some commands.
9−15V DC
PC
ct-17
mini-plug cable
IC-7600
RS-232C
cable
When the transceiver is connected to a PC with the
USB cable (third party), the optional CT-17 is not
required.