Operation Manual

D Command table
Cmd.
Sub cmd.
Data Description
00 see p. 157 Send frequency data (tr
ansceive)
01 see p. 157 Oper
ating mode selection for transceive
02 see p. 159 Read band edge frequenc
ies
03 see p. 157 Read oper
ating frequency
04 see p. 157 Read oper
ating mode
05 see p. 157 Set oper
ating frequency
06 see p. 157 Oper
ating mode selection for transceive
07 Select VFO mode
B0 Exchange ma
in and sub bands
B1 Equal
ize main and sub bands
C0 Turn the dualwatch OFF
C1 Turn the dualwatch ON
D0 Select ma
in band
D1 Select sub band
08 Select memory mode
0001 to
0099
Select memory channel
(0001=M-CH01, 0099=M-CH99)
0100 Select program scan edge channel P1
0101 Select program scan edge channel P2
09 Memor
y write
0A Memory to VFO
0B Memory clear
0E 00 Scan stop
01 Programmed/memory scan start
02 Programmed scan start
03
:F scan start
12 F
ine programmed scan start
13 F
ine :F scan start
22 Memory scan start
23 Select memory scan start
A1 Select
:F scan span ±5 kHz
A2 Select
:F scan span ±10 kHz
A3 Select
:F scan span ±20 kHz
A4 Select
:F scan span ±50 kHz
A5 Select
:F scan span ±100 kHz
A6 Select
:F scan span ±500 kHz
A7 Select
:F scan span ±1 MHz
B0 Set as non-select channel
B1 Set as select channel
( The previously set number by CI-V is set after
turning power ON, or “1” is selected if no selec-
t
ion is performed.)
01 Set as select channel “1”
02 Set as select channel “2”
03 Set as select channel “3”
B2 00 Set “ALL for select memory scan
01 Set “1” for select memory scan
02 Set “2” for select memory scan
03 Set “3” for select memory scan
D0 Set scan resume OFF
D3 Set scan resume ON
0F 00 T
urn the split function OFF
01 T
urn the split function ON
Cmd.
Sub cmd.
Data Description
10 00 Select 10 Hz (1 Hz) tun
ing step
01 Select 100 Hz tun
ing step
02 Select 1 kHz tun
ing step
03 Select 5 kHz tun
ing step
04 Select 9 kHz tun
ing step
05 Select 10 kHz tun
ing step
06 Select 12.5 kHz tun
ing step
07 Select 20 kHz tun
ing step
08 Select 25 kHz tun
ing step
11 00 Send/read attenuator OFF
06 Send/read 6 dB attenuator
12 Send/read 12 dB attenuator
18 Send/read 18 dB attenuator
12 0000 Send/read ANT1 select
ion (RX ANT OFF)
0001 Send/read ANT1 select
ion (RX ANT ON)
0100 Send/read ANT2 select
ion (RX ANT OFF)
0101 Send/read ANT2 select
ion (RX ANT ON)
13 00 Announce all data w
ith voice synthesizer
01 Announce frequency and S-meter le
vel with
voice synthesizer
02
Announce receive mode with voice synthesizer
14 01 0000 to
0255
Send/read [AF] level
(0000=max. CCW, 0255=max. CW)
02 0000 to
0255
Send/read [RF] level
(0000=max. CCW, 0255=11 o'clock)
03 0000 to
0255
Send/read [SQL] level
(0000=11 o'clock, 0255=max. CW)
06 0000 to
0255
Send/read [NR] level
(0000=0%, 0255=100%)
07 0000 to
0255
Send/read
inner [TWIN PBT] position
(0000=max. CCW, 0128=center, 0255=max. CW)
08 0000 to
0255
Send/read outer [TWIN PBT] pos
ition
(0000=max. CCW, 0128=center, 0255=max. CW)
09 0000 to
0255
Send/read CW p
itch
(
0000=300 Hz, 0128=600 Hz, 0255=900 Hz;
5 Hz steps)
0A 0000 to
0255
Send/read [RF POWER] level
(0000=max. CCW, 0255=max. CW)
0B 0000 to
0255
Send/read [MIC GAIN] level
(0000=max. CCW, 0255=max. CW)
0C 0000 to
0255
Send/read [KEY SPEED] level
(0000=max. CCW, 0255=max. CW)
0D 0000 to
0255
Send/read [NO
TCH] position
(0000=max. CCW, 0128=center, 0255=max. CW)
0E 0000 to
0255
Send/read COMP level
(0000=0, 0255=10)
0F 0000 to
0255
Send/read [BK-IN DELA
Y] position
(0000=max. CCW, 0255=max. CW)
10 0000 to
0255
Send/read [BAL] pos
ition
(0000=max. CCW, 0128=center, 0255=max. CW)
12 0000 to
0255
Send/read NB level
(0000=0%, 0255=100%)
14 0000 to
0255
Send/read DRIVE ga
in
(0000=0%, 0255=100%)
15 0000 to
0255
Send/read Mon
itor gain
(0000=0%, 0255=100%)
16 0000 to
0255
Send/read
VOX gain
(0000=0%, 0255=100%)
17 0000 to
0255
Send/read Ant
i VOX gain
(0000=0%, 0255=100%)
19 0000 to
0255
Send/read BRIGHT level
(0000=0%, 0255=100%)
15 01 00 Read squelch cond
ition (squelch close)
01 Read squelch cond
ition (squelch open)
02 0000 to
0255
Read S-meter level
(0000=S0, 0120=S9, 0241=S9+60 dB)
11 0000 to
0255
Read RF power meter
(0000=0%, 0143=50%, 0213=100%)
12 0000 to
0255
Read SWR meter
( 0000=SWR1.0, 0048=SWR1.5, 0080=SWR2.0)
13 0000 to
0255
Read ALC meter
(0000=0, 0120=Max.)
14 0000 to
0255
Read COMP meter
(0000=0 dB, 0130=15 dB, 0241=30 dB)
152
12
CONTROL COMMAND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21