D Data content description (continued)
Repeater tone/tone squelch frequency
setting
Command : 1B 00, 1B 01
100Hz digit: 0–2
10 Hz digit: 0–9
1 Hz digit: 0–9
0.1 Hz digit: 0–9
Fixed digit: 0*
Fixed digit: 0*
q*
00 X X X
w e
X
*Not necessary when setting a frequency.
• Band edge frequency setting
Command 02*, 1E 01, 1E 03
q
X X X
w e r t y u i o !0 !1 !2
X X X X X X X X X 2 D X X X X X X X X X X
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–6
1 MHz digit: 0–9
1000 MHz digit: 0 (fixed)
100 MHz digit: 0 (fixed)
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–6
1 MHz digit: 0–9
1000 MHz digit: 0 (fixed)
100 MHz digit: 0 (fixed)
Separator (fixed)
Lower edge Higher edge
Edge number*: 01–30
* Edge number setting is not necessary with com-
mand 02.
q, w Memory channel number
0000–0099
: Memory channel 0 to 99
0100 : Programmed scan edge P1
0101 : Programmed scan edge P2
e Select memory setting
00 : OFF
01 :
1
02
: 2
03 : 3
ri Operating frequency setting
See
“• Operating frequency.
o, !0 Operating mode setting
See “• Operating mode.
!1 Data mode setting
1 byte data (XX)
X X
!1
0: OFF, 1: TONE, 2: TSQL
0: OFF, 1: DATA 1, 2: DATA 2, 3: DATA 3
!2!4 Repeater tone frequency setting
!5!7 Tone squelch frequency setting
See “• Repeater tone/tone squelch setting.
!8@7 Memory name setting
Up to 10 characters.
S
ee Codes for memory name, opening message
and Clock 2 name contents.
159
12
CONTROL COMMAND
Memory content setting
Command : 1A 00
X
e ri o, !0 !1 !2!4 !5!7
X X X ... ...X X X X X X X X X X X X X X X X X XX XX X X X X X X X
q, w !8@7