Operation Manual
195
18
CONTROL COMMAND
D Data content description (continued)
q Frequency band setting
00 : HF/50 MHz frequency band
01 : 144 MHz frequency band
02 : 430 MHz frequency band
03 : 1200 MHz frequency band
w, e Memory channel number
0001–0099 : Memory channel 1 to 99
0100 : Programmed scan edge 1A
0101 : Programmed scan edge 1b
0102 : Programmed scan edge 2A
0103 : Programmed scan edge 2b
0104 : Programmed scan edge 3A
0105 : Programmed scan edge 3b
0106 : Call channel
r Split and Select memory settings
XX
r
0: Select memory OFF
1: Select memory ON
0: Split OFF
1: Split ON
When the program channel is selected, both settings
should be “0.”
When the Call channel is selected, the Select mem-
ory setting should be “0.”
t–o Operating frequency setting
See‘•Operatingfrequency.’(p.190)
!0, !1 Operating mode setting
See‘•Operatingmode.’(p.190)
!2 Data mode setting
1 byte data (XX)
00: Data mode OFF
01: Data mode ON
!3 Duplex and Tone settings
XX
!3
0: OFF, 1: Tone
2: TSQL, 3: DTCS
0: Duplex OFF
1: Duplex−, 2: Duplex+
!4 Digital squelch setting
X0
!4
0: Digital squelch function OFF
1: Digital call sign squelch function ON (DSQL)
2: Digital code squelch function ON (CSQL)
!5–!7 Repeater tone frequency setting
!8–@0 Tone squelch frequency setting
See‘•Repeatertone/tonesquelchfrequencysetting.’
(p. 193)
@1–@3 DTCS code setting
See‘•DTCScodeandpolaritysetting.’(p.193)
@4 Digital code squelch setting
See‘•Digitalcodesquelchsetting.’(p.193)
@5–@7 Duplex offset frequency setting
See‘•DuplexOffsetfrequencysetting.’(p.192)
@8–#5 Destination call sign setting
(8characters;xed)
#6–$3 R1 (Access/Area repeater) call sign setting
(8characters;xed)
$4–%1 R2 (Link/Gateway repeater) call sign setting
(8characters;xed)
See‘•DVTXcallsignssetting.’(p.194)
%2–^0 Memory name setting
9 characters (Fixed)
See‘•Charactercodesetting.’(p.190)
About clearing operation:
“1A 00” command with the format as below clears the
data of the selected memory channel.
w, e : Memory channel 0 to 99
r : FF
t or later : None
NOTE:
•Thesamedataast–%1 are stored in t–%1.
•WhentheSplitfunctionisON,thedataoft–%1
is used for transmit.
•EveniftheSplitfunctionisOFF,enterthedata
into t–%1 to match your transceiver. We recom-
mend that you set the same data as t–%1.
• Memory content setting
Command : 1A 00
X
rqt∼o!0、!1 !2 !4 @4!3 !5∼!7 @5∼@7@1∼@3!8∼@0
XXX…… XXXXXXXXXXX0XXXXXXXX XXXX XX XXXXXXXX XXXXXX XXXX
w、e
$4∼%1
XX…… XX ……………… ……XX XX
t∼%1 %2∼^0#6∼$3
XX…… XX
@8∼#5
XX…… XX