User Guide

21
7
CALL PROCEDURE
7
2001 NEW
DD
Individual call operation
q Push [MODE
SET
] to select the DSC menu.
w Rotate [CH] to select Individual, then
push [ENT].
e Select (or enter)
the 9-digit ID code, then push
[ENT].
Use [CH] to select the ID code when the desired ship’s
ID is pre-programmed.
Select “Manual set” with [CH] then push [ENT],
after that, enter the desired 9-digit ID via the keypad.
r Rotate [CH] to select the desired pre-programmed
traffic frequency, or “Manual set” then push
[ENT].
When the pre-programmed traffic frequency is
selected, go to step t.
When “Manual set” is selected, enter the desired
calling frequency via the keypad.
t Rotate [CH] to select the desired pre-programmed
calling frequency, or “Manual set” then push
[ENT].
When the pre-programmed call frequency is se-
lected, go to step y.
When “Manual set” is selected, enter the desired
calling frequency via the keypad.
y The calling stand-by screen is displayed as fol-
lows, verify the calling condition then push and
hold [CALL] for 1 sec. to transmit the call.
Push and hold [ENT] for 1 sec. to store the calling con-
dition into the TX memory described in pages 22 and
37, if desired.
u After sending the call, the transceiver waits for an
acknowledgement.
Continue to the next page
F1B
GPS
<
Wait
for
ACK
>
Individual
Lat
34
34'N
Lon135
34'E
12:34
Exit
******
Individual
******
---------
Call
---------
To:IC-M801_1
Category:Routine
Traffic:J3E
TX
2134.0kHz
RX
2134.0kHz
Call
Freq:TX
2177.0kHz
RX
2177.0kHz
Call
Write-Menu
******
Individual
******
----
Call
frequency
----
TX:
2177.0kHz
RX:_2177.0kHz
OK
******
Individual
******
----
Call
frequency
----
Manual
set
T:
2177.0kHz
SHIP
R:
2177.0kHz
T:
2189.5kHz
INTER2-1
R:
2177.0kHz
Ç
OKSEL
******
Individual
******
--
Traffic
frequency
---
TX:
2134.0kHz
RX:_2134.0kHz
OK
******
Individual
******
--
Traffic
frequency
---
Manual
set
T:
2134.0kHz
IC-M801-1
R:
2134.0kHz
T:12345.0kHz
IC-M801-2
R:12345.0kHz
Ç
OKSEL
******
Individual
******
------
Address
ID
------
OK
________
******
Individual
******
------
Address
ID
------
Manual
set
IC-M801-1
123456789
IC-M801-2
123456788
IC-M801-3
123456787
IC-M801-4
123456786
IC-M801-5
123456785
Ç
OKSEL
IC-M801E_0.qxd 05.12.2 16:32 Page 21