User Guide
25
7
CALL PROCEDURE
7
e Rotate [CH] to select “Urgency,” then push
[ENT].
r Rotate [CH] to select a traffic frequency from one
of the pre-programmed frequencies or “Manual
set” then push [ENT].
✔ When a pre-programmed frequency is selected,
go to step y.
t Enter the desired traffic frequencies for both the
transmit and receive, then push [ENT].
y Rotate [CH] to select the desired calling channel,
then push [ENT].
u After the calling stand-by screen appears, push
and hold [CANCEL/CALL] for 1 sec. to transmit the
urgency call.
•The transceiver is set to the traffic frequency after the
call transmission.
•Push and hold [ENT] for 1 sec. to store the calling con-
dition into the TX memory described in pages 23 and
43, if desired.
i Announce the following message.
•“PAN PAN”
•“All stations” (repeated 3 times).
•“This is ..... (your ship name).”
•The 9-digit identity AND the call sign (or
other identification of the ship)
• The text of the urgency message.
******
All
ships
*******
---------
Call
---------
Category:Urgency
Traffic:J3E
TX
2134.0kHz
RX
2134.0kHz
Call
Freq:TX
2187.5kHz
RX
2187.5kHz
Write-Menu
Call
******
All
ships
*******
----
Call
frequency
----
2187.5kHz
4207.5kHz
6312.0kHz
8414.5kHz
12577.0kHz
16804.5kHz
Ç
OKSEL
******
All
ships
*******
--
Traffic
frequency
---
TX:_2134.0kHz
RX:_2134.0kHz
OKSEL
******
All
ships
*******
--
Traffic
frequency
---
Manual
set
T:
4567.0kHz
IC-M802-1
R:
4567.0kHz
T:12345.0kHz
IC-M802-2
R:12345.0kHz
Ç
OKSEL
******
All
ships
*******
-------
Category
-------
Safety
Urgency
Ç
OKSEL
DD
Urgency call operation
q Push [MODE
SET
] to select the DSC menu.
w Rotate [CH] to select either “Individual” or
“All ships” then push [ENT].
• When selecting “All ships”
IC-M802_USA.qxd 02.7.9 10:58 Page 25