Operation Manual

10
4
BATTERY CHARGING
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Connecting BC-226 together
You can connect up to 6 BC-226 together.
1. Remove the charger’s right cover. (q)
2. Snap the DC power plug to the other charger’s DC
power jack. (w)
WARNING: DO NOT connect more than 6 chargers
together. It may result in an electric shock, cause a re,
overheating, or damage chargers.
D Information
Status indicator
Light color Status
Orange Charging
Green Charging is completed.
Blinks orange and green Charging failed. It may have some
problems.
BC-226 Fuse replacement
If a fuse blows, nd and repair the cause of the problem.
Then replace the damaged fuse with a new, adequately
rated fuse.
Fuse type: 5 A/58 V (low prole mini blade fuse)
NOTE:
The transceiver MUST be turned OFF while charging.
Otherwise:
- The battery will not be charged correctly.
- The battery life may be shortened.
Do not transmit while charging. When you need to
transmit, remove the transceiver from the charger, and
then turn ON the power.
If the battery pack does not properly charge when it is
attached to the transceiver, remove it from the transceiver
and insert only the battery pack into the charger.
NOTE: Remove the fuse using the needle-nose pliers.
Fuse