America Inc. Fish Finder User Manual

Connecting the units
NMEA1 connection NMEA2 connection
Power source requirement
D DC power source
The radar is designed for connection to any power
source if the voltage is 10.242 V DC, so that a 12, 24,
or 32 V DC battery can be used without a DC-DC con-
verter, or any internal modications.
DC power cable connection
Connect the supplied DC power cable as shown in the
diagram.
Ground connection
To prevent electrical shocks and other problems, ground the display unit through the [GND] terminal on the units
rear panel. For best results, connect a heavy gauge wire or strap to the nearest grounding point on the boat. The
distance between the [GND] terminal and the ground point should be as short as possible.
CAUTION: Incorrect cable connection may dam-
age the radar.
DC input
Ground
q N TXT
(NMEA 2 output)
w RXD
i GND
u N.C
y AUX input (); CLOCK
or N+1() data input
t AUX input (+); CLOCK
or N+1(+); data input
r NMEA 1 input ()
or AUX input (); DATA
e NMEA 1 input (+)
or AUX input(+); DATA
NMEA1:
Bearing data input
NMEA2:
NMEA 0183 data input
Speed sensor input
+
Ground
Power supply
10.2 to 42 V DC
Red:
Black: _
PWR
GND
NEVER connect any-
thing other than the sup-
plied scanner unit.
Supplied scanner unit
9
INSTALLATION AND CONNECTIONS
24
q NMEA 2
output (+)
w NMEA 2
output ()
e NMEA 2
input (+)
u GND (Speed sensor)
y Speed sensor
input
t Regulated 12 V output.
(20 mA Max.)
r NMEA 2 input ()
MR-1000R2_T2.qxd 04.2.24 10:22 Page 24