INSTRUCTION MANUAL VHF-UHF FM REPEATER X BAND 50 REPEATER 1
IMPORTANT EXPLICIT DEFINITIONS READ THIS INSTRUCTION MANUAL CAREFULLY before attempting to operate the WORD WARNING DEFINITION SAVE THIS INSTRUCTION MANUAL– This CAUTION NOTE Equipment damage may occur. repeater. manual contains important safety and operating instructions for the series. PRECAUTION Personal injury, fire hazard or electric shock may occur. If disregarded, inconvenience only. No risk of personal injury, fire or electric shock.
FORWARD SUPPLIED ACCESSORIES Thank you for purchasing this Icom America Systems X—BAND 50 VHF/UHF FM REPEATER. With proper care, this product should provide you years of trouble-free operation. The following accessories are supplied with X—Band 50 series FEATURES [AC120V version] ➀ AC power cable (OPC-510) ….............……… 1 ❍ Automatic battery backup charging system A built-in backup system supports automatic switching to an external power supply (13.
1 PANEL DESCRIPTION ■ Front Panel ➎ ➊ ➋ ➌ ➊ MICROPHONE/SPEAKER CONNECTOR [MIC/SP] This 8-pin modular jack accepts the optional microphone. ➀ ➇ 1 ➀ +8 V DC output (Max. 10 mA) ➁ I/O port for PC programming ➂ AFO ➃ M PTT (Input port for TX control) ➄ Microphone ground ➅ Microphone input ➆ Ground ➇ CLI (Input port for monitor control) ➍ ➋ VOLUME CONTROL [VOLUME] Adjusts the audio output level.
PANEL DESCRIPTION 1 ■ Front Panel ➊ ➋ ➏ ➎ ➍ ➌ ➊ AF VOLUME CONTROL KNOB Rotate the knob to adjust the audio output level. • Minimum audio level is pre-programmed. ➋ FUNCTION DISPLAY Displays a variety of information, such as an operating channel number/name. NOTE: The above functions depend on pre-programming. ➌ POWER SWITCH [POWER] Push to turn the power ON and OFF.
PANEL DESCRIPTION 1 ■ Rear Panel ➋ ➎ ➌ Connects the supplied AC power cable to a domestic AC outlet. ➋ POWER SWITCH [POWER] Toggles to turn the repeater power ON or OFF. Located on the back panel of the repeater. ➌ RIGHT Radio ANTENNA CONNECTOR ➥ Connect the correct band antenna (impedance: 50 Ω). ➍ LEFT Radio ANTENNA CONNECTOR ➥Connect the correct band antenna (impedance: 50 Ω).
PANEL DESCRIPTION 1 ■ Repeater Controller Programming Both Mobile Radios CS-F3020/F5010/F5020 • 0Go to LMR>Memory CH>1: Program the TX and RX •0 Set the CTCSS/CDCSS Tone •0 Set RF Power to High • 0LMR > External I/O > Option IGN SW = inhibit Ext. EPTT > Tone Mute EPTT = off Ext. Out (EXO) / Horn > RX EXO = on • LMR External 1/0 > Port Settings EXT. I/O 4 Output Null EXT. I/O 6 Output Null EXT. I/O 7 AFO EXT. I/O 10 Null EXT. I/O 11 Audible EXT.
5 Fig.
Solder Fig.
PANEL DESCRIPTION 1 ■ Accessory connector DB25 Pin Outs Configuration 7 Radio on Right Pin Pin Name No. 6 Vcc 7 GND 8 Busy +15V DC Supply for Internal Device DC Ground, UHF Unit Output Terminal for Busy Signal 9 10 11 12 13 Audio Output Discriminator Output Transmit Audio External PTT Transmit Data Input AFO DISC TXA PTT TXD Description Radio on Left Description Pin Pin Name No.
2 INSTALLATION AND CONNECTIONS ■ Unpacking After unpacking, immediately report any damage to the delivering carrier or dealer. Keep the shipping cartons. For a description and a diagram of accessory equipment included with the X-BAND 50 series, see ‘Supplied accessories’ of this manual.
INSTALLATION AND CONNECTIONS 2 ■ Required Connections [DC POWER INPUT TERMINAL] Make sure the back up battery is correctly connected. Use a cable with following current capacity. Solder or clamp the cable plug when connecting the power cable to the backup battery to prevent voltage drops. Power cable current capacity: 25 A or more TX - RX ANT VHF or UHF TX•RX antenna required. 9 VHF RX - RX ANT VHF or UHF TX•RX antenna required.
INSTALLATION AND CONNECTIONS 2 ■ Power Make sure the [POWER] switch is turned OFF when connecting an AC power cable and a backup battery (emergency power supply). The X-Band 50 series can operate with an AC or DC power supply. If AC power is interrupted when operating the repeater with an AC power supply, power is automatically provided to the [BATTERY] terminals. Battery will be automatically recharged when AC power is restored.
3 Optional Unit Installation ■ Opening the repeater’s case Follow the case and cover opening procedures shown here when an optional unit is installed or adjust the internal units, etc. CAUTION: Disconnect the AC power cable and/or DC power cable from the repeater. Otherwise, there is danger of electric shock and/or equipment damage. ➀ Remove 7 screws from the top of the repeater and 1 screw from the top front, then lift up the top cover.
4 LOCAL OPERATION ■ CROSS BAND OPERATION ■ Turning power ON ➀ On rear panel, push [POWER] to turn power ON. ■ Receiving and transmitting Receiving ➀ Push [POWER] to turn power ON. ➁ Rotate [VOLUME] to adjust the audio output level. ➂ Push to select the desired channel. • When receiving a signal, BUSY indicator turns ON and audio is emitted from the speaker. • Further adjustment of [VOLUME] to a comfortable listening level may be necessary at this point.
5 MAINTENANCE ■ Fuse replacement If a fuse blows or the repeater stops functioning, try to find the source of the proble, and replace the damaged fuse with a new, rated fuse. Replace the circuitry fuse as shown below. “There are two fuses for each radio The left fuses are for Left Radio The right fuses are for Right Radio RWARNING: DISCONNECT the AC power cable and/or DC power cable from the repeater. Otherwise, there is a danger of electric shock and/ or equipment damage.
6 SPECIFICATIONS AND OPTIONS ■ Specifications Specification ◆ X-Band 50 VHF • Frequency coverage Wide Narrow • Number of programable channels • Antenna impedance • Operating temperature range GENERAL • Type of emission • Power supply requirement • Current drain (approx.) • Dimensions (projections not included) • Weight • TX output power TRANSMITTER • Modulation • Max. permissible deviation • Frequency error • Spurious emission • Adjacent channel power (nominal) RX TX Stand-by Max.
SPECIFICATIONS AND OPTIONS 6 Specification ◆ X-Band 50 UHF • Frequency coverage GENERAL • Type of emission Wide Narrow • Number of programable channels • Antenna impedance • Operating temperature range • Power supply requirement • Current drain (approx.) (nominal) RX TX • Dimensions (projections not included) RECEIVER TRANSMITTER • Weight • Transmit output power • Modulation 15 • Max.
16