Operation Manual

34
6
SCAN OPERATION
New2001
6
Auto memory write scan
This scan is useful for searching a specified frequency
range, and automatically storing busy frequencies into
memory channels. The same frequency ranges used for a
program scan are also used for an auto memory write scan.
q
Start a VFO scan.
Push [V/M] to select the VFO mode.
Set the squelch level.
Hold down [SCAN](MODE) for 1 second to enter the
scan type selection mode.
Rotate [DIAL] to select a desired scanning type.
Select “ALLfor full scan, “BANDfor band scan, P-LINK
x” for programmed link scan (x= 0 to 9), “PROGxx” for pro-
grammed scan (xx= 0 to 24; only programmed scan edge
numbers are displayed).
Push [SCAN](MODE) to start the scan.
w
Push [V/M] to turn the auto memory write function ON or
OFF.
The “ icon blinks.
• Push [SCAN](MODE) to stop the scan.
[DIAL]
During auto memory
write scan
The icon blinks
during auto memory
write scan.
D During auto memory write scanning:
When a signal is received, the scan pauses for approxi-
mately 5 seconds and the frequency is stored into an
auto memory write channel group (
AW
000–
AW
199).
- 2 short beeps sound when stored.
The scan resumes after frequency storing.
When all channels are stored, the scan automatically
stops and 1 long beep sounds.
D Re-calling the stored frequencies:
q Push [V/M] to select the memory mode.
w Push [BAND] repeatedly, or while holding down [BAND],
rotate [DIAL], to select the auto memory write channel group.
• “AW” appears.
e Rotate [DIAL] to select a desired channel.
“AW” appears when the
auto memory write channel
group is selected.
D Clearing the stored frequencies:
q Select the auto memory write channel group.
w While holding down [FUNC], push and hold [S.MW](V/M)
for 1 second to clear all the channels’ contents.
• 1 short and 1 long beep sounds.
NOTE: The auto memory write channel contents CANNOT
be cleared by an independent channel. Thus it is a good
idea to copy the contents into a regular memory channel.