SCAN OPERATION
New2001
D Scan pause timer
The scan pauses when receiving signals, according to the
scan pause time. It can be set from 2–20 seconds, or unlim-
ited.
q
Hold down [SET](TS) for 1 second to enter the Set mode.
w
Rotate [DIAL] to select the “EXPAND” item.
e
While holding down [FUNC], rotate [DIAL] to turn the
Expand set mode selection ON.
r
Rotate [DIAL] to select the “PAUSE” item.
t
While holding down [FUNC], rotate [DIAL] to set a
desired scan pausing time from 2–20 seconds (2 seconds
steps) or “HOLD.
• “2SEC”–“20SEC” : The scan pauses 2–20 seconds while receiv-
ing a signal.
• “HOLD” : The scan pauses on a received signal until it
disappears.
y Push [SET](TS) to exit the Set mode.
[DIAL]
After 1 sec.
D Scan resume timer
The scan resumes after a signal disappears, according to
the resume time. It can be set from 0–5 seconds, or unlim-
ited.
q
Hold down [SET](TS) for 1 second to enter the Set mode.
w
Rotate [DIAL] to select the “EXPAND” item.
e
While holding down [FUNC], rotate [DIAL] to turn the
Expand set mode selection ON.
r
Rotate [DIAL] to select the “RESUME” item.
t
While holding down [FUNC], rotate [DIAL] to set a
desired scan pausing time from 0–5 seconds (1 second
steps) or “HOLD.
• “0SEC” : The scan resumes immediately after the sig-
nal disappears.
• “1SEC”–“5SEC” : The scan resumes 15 seconds after the
signal disappears.
• “HOLD” : The scan resumes only by rotating [DIAL].
y Push [SET](TS) to exit the Set mode.
After 1 sec.
The scan resume timer must be set shorter than the scan
pause timer, otherwise this timer will not be activated.
Scan resume setting
using EXPAND SET MODE