TM Managed Switch Console Manual Industrial Managed Ethernet Switch Version 1.0 This document applied to models of MSM-508,MSM-508FC/FCS/FT Co p yr i gh t © IC P D A S C o. , Lt d. , A l l R i gh ts Re s er ve d . Release No.
CONTENTS 1. Console Connection........................................................................................ 2 2. Console Command ......................................................................................... 4 ▓ ? [COMMAND] 4 ▓ REBOOT/RESET 4 ▓ DEFAULT 5 ▓ IP 5 ▓ MASK 6 ▓ GATEWAY 6 ▓ MAC 6 ▓ NETID [id number] ▓ LMASK [mask value] 8 ▓ CMASK [mask value] 9 ▓ SMASK [mask value] 9 ▓ LVALUE 10 ▓ CMASK 10 ▓ SMASK 11 ▓ HMIVALUE Release No.
Industrial Redundant Ring Switch – Managed Switch Console Manual Managed Switch RS-232 & Telnet Console Operation ICPDAS Managed Switch provides three access Console Connection Console Command methods, RS-232, Telnet and HTTP, to configure the Switch functions. This Manual will guide you how to use the RS-232 and Telnet to access Managed Switch console. Release No.
Industrial Redundant Ring Switch – Managed Switch Console Manual 1. Console Connection RS-232 Connection ICPDAS RS Series Switch is shipped with a 9-pin Female D-sub & RJ-45 cable (CA-090510),please use this cable to connect Switch’s RS232 port with PC’s COM port. You can connect to Switch console by using windows Terminal Emulator, Baud Rate : 115200 Data Bits :8 Parity : none Stop Bit :1 Otherwise, you can download our free Console Emulator from RS Series Switch download page: http://www.
Industrial Redundant Ring Switch – Managed Switch Console Manual By factory default setting, both the account and password are Admin. Only one telnet connection is accepted at the same time. Release No.
Industrial Redundant Ring Switch – Managed Switch Console Manual 2. Console Command ▓ ? [COMMAND] Description Both “help” and “?” display a list of available commands, if parameter is not specified. The [command] parameter is used to see detail information for a specific command Parameters Parameter Description command Please provide the name of the command that you want detail information about. Example ▓ REBOOT/ /RESET Description The reset command will initiate Ring Switch a self-restart.
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ DEFAULT Description The default command will restore all settings to factory default values. Current factory default values are as follow: COM1:baudrate 115200,8bit,none patity check, 1 stopbit COM2:baudrate 115200,8bit,none patity check, 1 stopbit link mask:0 communication mask:0x1f status mask:0x3 netid:1 mac: factory-set unique MAC address ip:192.168.255.1 mask:255.255.255.
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ MASK Description If no mask address is specified, the “mask” command will display current mask address. To assign a mask address for TCP/IP, please input mask address in the form of “m1.m2.m3.m4” (each field contains a value in the range 0 – 255). Example ▓ GATEWAY Description If no gateway IP address is specified, the “gateway” command will display current gateway address.
Industrial Redundant Ring Switch – Managed Switch Console Manual Example Each Switch is shipped from the factory with a unique MAC address, and the value is labeled on the Switch case. DO NOT change this address unless you have a good reason to do so. ▓ NETID [id number] Description If Net ID of Modbus is not specified, the “netid” command will display current ID number of Modbus. The command parameter [id number] is used to assign a specific ID number for Modbus Net ID.
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ LMASK [mask value] Description This command enables you to configure relay output activation status when there is link loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0 corresponds to port 1, etc.
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ CMASK [mask value] Description This command enables you to configure relay output activation status when there is communication loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0 corresponds to port 1, etc. The bits mapping please refer to TABLE 1. (LMASK command) Example cmask 0x1a Set Relay active if communication lose on Port 2, 4, or port 6.
Industrial Redundant Ring Switch – Managed Switch Console Manual Set Relay active if Power 1 or Power 2 fail ▓ LVALUE Description This command enables you to read link status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. Bit 0 corresponds to port 1, etc. If there is link loss occurring on port(s), the corresponding bit(s) will be set up as 1. Example Link loss occurring on port 2,3,4,5,6 and 8.
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ SMASK Description This command enables you to read system status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. bit 0 Corresponding to: Power 1 Description If there is a power fail occurring on Power 1, bit 0 will be set as 1. 1 Power 2 If there is a power fail occurring on Power 2, bit 1 will be set as 1.
Industrial Redundant Ring Switch – Managed Switch Console Manual Example ▓ RTIME [time] Description Recovery time is the length of time it takes to return back to normal operation after an error or other failure has occurred. This command enables you to set up the recovery time in millisecond (ms). Parameters Parameter Description time Provides the time interval(ms) that you want to set up as the recovery time Example Return message: “recovery time X (Y) ms.
Industrial Redundant Ring Switch – Managed Switch Console Manual [Round (0.3*(5+1))]*100 = Round (1.8) *100 =2*100 =200 ms If the recovery time is not longer enough, the Master LED will keep on flashing to make a warning. ▓ FTIME [time] Description This command enables you to set up the spanning tree bridge forward delay in milliseconds (ms) . Forward delay is the time interval spent waiting to change a port from its spanning tree pre-forwarding state to a forwarding state.
Industrial Redundant Ring Switch – Managed Switch Console Manual Parameters Parameter Description time Provides the time interval(ms) that you want to set up as the maximum time Example Return message: “max age time X (Y) ms. ” “X” ( switch value) indicates the mtime value set by console command, “Y” (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting).
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ COM1 [baud rate][data bit][parity][stop bit] Description The first serial port Com1 is assigned for RS232. This command enables you to set up the transmission speed (baud rate),data bit (data bit), parity check type (parity) and stop bit (stop bit). The transmission speed parameter [baud rate] allows the following settings: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. The port speed and device speed must match.
Industrial Redundant Ring Switch – Managed Switch Console Manual ▓ COM2 [baud rate][data bit][parity][stop bit] Description The second serial port Com2 is assigned for RS485. This command enables you to set up the transmission speed (baud rate),data bit (data bit), parity check type (parity) and stop bit (stop bit). Setting parameters are the same as COM1. Release No.