FIGURE 12 Accessory Electric Heater Heating Data
*TemperatureRise °F @ CFM
Heater
Model
AMMK05AHA
AMMK05AHB
AMMK07AHA
AMMK07AHB
AMMK10AHA
AMMK10AHB
AMMK15AHB*
AMMK20AHB**
UseWith
NC: 2-5 TON
NC: 2-5 TON
NC: 2-5 TON
21/2-5 TON
21/2-5 TON
SupplyVoltage KWHating
240-1-60 4.8
208-1-60 3.6
240-1-60 7.5
208-1-60 5.6
240-1-60 9.6
208-1-60 7.2
240-1-60 14.4
208-1-60 10.6
240-1-60 19.2
208-1-60 14.4
TotalHeating
BTUH 600 800
16,832 25.3 t9.0
12,287 19.0 t4.2
25,596 39.5 29.6
19,113 29.5 22.t
32,765 50.6 37.9
24,574 37.9 28.4
49,147 --- 56.9
36.860 56.9 42.7
65,530 ......
49,147 --- 56.9
1000 1200 1400 1600 1800 2000 2200
15.2 12.6 10.6 9.5 8.4 7.6 ---
11.4 9.5 8.1 7.1 6.3 5.7 ---
23.7 19.8 16.9 14.8 13.2 11.9 10.8
17.7 14.7 12.6 11.1 9.8 8.8 8.0
30.3 25.3 21.7 19.0 16.9 15.2 13.8
22.8 19.0 16.3 14.2 12.6 11.4 10.3
45.5 37.9 32.5 28.4 25.3 22.8 20.7
34.1 28.4 24.4 2t.3 19.0 17.1 15.5
- - - 50.6 43.3 37.9 33.7 30.3 27.6
45.5 37.9 32.5 28.4 25.3 22.8 20.7
* 15 KWHEATERNOTTO BE OPERATEDON LOWTAP FOR2 1/2 TON NC AND HP.
** 20 KWHEATERNOTTO BE OPERATEDON LOW ORMEDIUMLOWTAP FOR 3 AND 3 1/2 NC AND HP.
Unit Disconnect Breaker
FIGURE 13 l Installing Circuit Breaker
SpringClipReleaseTab
Rain Shield Installation
FIGURE 14 I Installing The Rain Shield
1
CLOSED CELL FOAM PAD
1/8" THICK 3 3/8' X 71/16"
IN SIZE, ADHESIVE BACKED.
INSIDE
CIRCUIT BREAKER COVER.
BREAKER
HEATER PLUGS
RAIN SHIELD
1. Removeallscrewsfromthecoverplateon Blower/ElectricalAccessPanel.
Ifa seperateunitdisconnectbreaker/switchisrequireditcan beinstalledinsidetheunitin 2. Installadhesivebackedgasketon Blower/ElectricalAccess Panel.
the heateraccessoryorasa singleinstallationbyusingthe DisconnectSwitchKit.A sep
eratepowersupplycircuitmustbe providedforthe unit. 3. Installlower frame of rainshield with4 screws.
1.Toinstallthe circuitbreakerorswitch,insertthe bottomfoot of thebreaker intolower
mounting holeon the heater panelwiththe breakerat a slightangleout fromthe 4. Installrain shieldhingedcoverwith4 screws.
panel.
2. Pushbreakerin towardspanelandlift up slightlyso breakerfits intothe top mount-
ingholeand snaps (locks)inposition.
Breakershavea lockingspringcliptoholdthem inposition.Toremovebreakerlift upon
the releasetab on top of the breakerand pullout and downslightly.
FIGURE 15 Accessory Electric Heater Heating Data
5. Installcircuitbreakerfillerplates(2eachper unusedbreakerslot.)
6. Re-installBlower/ElectricalAccess Panel.
NOTE: VERIFYALLAPPROPRIATESEALSARE iN PLACE.SEE FIGURE14.
Breaker Amps Part Number Application
25 1082008 PA9524, PA5524, PAPA24, PAPC24
30 1082009 PA9530, PA5530, PAPA30, PAPC30
35 1082010 PA5536, PAPA36
40 1082011 PA9536, PAPC36
45 1082012 PA9542, PAPC42
50 1082013 PA5542, PA5548, PAPA42, PAPA48
60 1082014 PA9548, PAPC48
60 Switch 1082042 Fits AII- Disconnect Switch Only (No Over Current Protection)
AMMO01 DSA DISCONNECT SWITCH KIT (includes 60A switch & rain shield) BREAKER FOR UNIT ONLY.
FOR "NO HEAT" or PIGTAIL STYLE HEATER APPLICATION ONLY.