User's Manual

50
* Default Output Setting for Input Sources
9.6.1 EXIT BUTTON OUTPUT SETTING
9.6.2 DOOR CONTACT OUTPUT SETTING
9.6.3 AUX INPUT#1 OUTPUT SETTING
9.6.4 AUX INPUT#2 OUTPUT SETTING
9.6.5 TAMPER ALARM OUTPUT SETTING
9.6.6 DURESS ALARM OUTPUT SETTING
Output Time setting for above Input Sources are the same as 9.6.1 Exit Button Output setting.
OUT PUT
Door
Relay
(DR)
Alarm
Relay
(A R)
T T L #1
(T 1)
T T L #2
(T 2)
Buzzer
(BZ)
[ 1] E X IT BUT T ON 03 00 00 00 00
[ 2] DOOR CONT A CT 00 99 00 00 00
[ 3] A UX Input #1 00 00 00 00 00
[ 4] A UX Input #2 00 00 00 00 00
[ 5] T A MPE R A L ARM 00 99 99 99 99
[ 6] DURE SS A L ARM 00 00 00 00 00
[ 7] OUT PUT T IME SCHE DUL E 00 00 00 00 00
[ 8] INPUT T IME SCHE DUL E 00 00 00 00 00
[ 9] INPUT T Y PE 00 00 00 00 00
. You can program OUTPUT activating time when the EXIT button pressed. The value put here is value x
second when the Time Unit set to 1 second and value/10 second when the Time Unit set to 0.1 sec.
You can set the time from 00 to 98 seconds (0.0 to 9.8 seconds if Time Unit set to 0.1 sec.) and if you put the
value “99”, the Output will activate forever until you reset the Output.
Press <4> or <6> key to select Input Sources then press <ENT> key to program the Output time.
DR: Door Relay Output
AR: Alarm Relay Output
T1: TTL#1 Output
T2: TTL#2 Output
BZ: Buzzer Output