5.2 BACKUP BATTERY SWITCH
GE314 has a switch for the backup battery connection, which remains open circuit to prevent any current
consumption of the backup battery (Figure: Switch setting). Before the GE314 operation, it needs to be
connected so that the backup battery can retain the serial RTC(Date and Time data) during power failure.
Fi gure: SWITCH SETTING Fi gure: SWITCH LOCATION
5.3 SYSTEM INITIALIZATION
After the all installation and connections are completed, press and hold the Initialize button and put the power
(+12V DC) to GE314. The LCD will first display βInitialize OK? 0:No 1:Yesβ. Press <1> key if you want to
initialize the system. After all Initialization process is completed, the system is operating on normal mode and
the LCD displays βGE Security, GE314 [F1], Date Timeβ.