APPENDIX
A. THE RELATION BETWEEN INPUT AND OUTPUT (DEFAULT)
* Default Output Setting for Input Sources
* Index No. [1] ~ [6]:
The value indicates operation time (second) of each output for the input signal.
* Index No. [7]:
The value indicates time schedule code (index) that each output operation has to
be applied.
* Index No. [8]:
The value indicates the time schedule code (index) that each input #1(Exit
button) ~#5 operation has to be applied.
* Index No. [9]:
The value indicates the type of each input #1(Exit button) ~#5 operation.
The “00” is NO(Normal Open) type.
The “01” is NC(Normal Close) type.
OUT PUT
INPUT
Door
Relay
(DR)
Alarm
Relay
(A R)
T T L #1
(T 1)
T T L #2
(T 2)
Buzzer
(BZ)
[ 1] E X IT BUT T ON 03 00 00 00 00
2] DOOR CONT ACT
00 99 00 [ 00 00
[ 3] A UX Input #1 00 00 00 00 00
[ 4] A UX Input #2 00 00 00 00 00
[ 5] T A MPE R A L ARM 00 99 99 99 99
[ 6] DURE SS A L ARM 00 00 00 00 00
00
00 00 00 00
00 00 00 00 00
[ 7] OUT PUT T IME SCHE DUL E
[ 8] INPUT T IME SCHE DUL E
[ 8] INPUT T Y PE 0 00 00 00 00 0