6. INSTALLATION TIPS & CHECK POINTS
Please refer to information below to stably operate the LX006.
6.1 CHECK POINTS BEFORE INSTALLATION
6.1.1 CABLE SELECTION
(Figure: System configuration)
6.1.2 RECOMMENDED CABLE TYPE AND PERMISSIBLE LENGTH OF CABLE
* Thicker wires are required if you connect the reader with high current consumption.
6.1.3 READER CONNECTION
If you install the reader in a long distance between the ACU and the reader, you should be aware
there could be voltage drop between ends of GND wire. For example, if you connect a reader with
100mA current consumption at 100m distance (assume to using DC resistance of cable of
100/100m) and the reader power is supplied from the ACU, the voltage drop of the GND wire will
be 1V. In this case, the Wiegand data signal cannot be measured lower than 1V.
No
Description
Cable
specification
Maximum
distance
1
LX006 Power (DC+12V)
DC Power -> LX006
Belden #9409,18 AWG
2 conductor, unshielded
3m
*2
RS232 Cable converter->Host P.C.
Belden #9829, 24 AWG
2-twisted pair, shielded
15m
3
RS485 Cable
LX006 -> LX006
LX006 -> Converter
Belden #9829, 24 AWG
2-twisted pair, shielded
1,200m
POWER