b) Registration Using Keypad
NOTE| In case you make a typing mistake during the registration process, you can press F1
button to erase your errors.
1. Scanning – means the reader is waiting for an ID number to be entered. The card number
for the card will appear with a beep sound when you present the card.
2. ID – is a Personal Identification Number (PIN) that consists of 4-8 digits. Enter a 4-8digit ID
number (PIN) and press <ENT> key. (For LX505SR, the ID number consists of 4-10 digits.
3. PW – stands for a password that is required for verification in the RF + Password operating
mode.
4. TA – refers to the Time Schedule code (‘00’ ~ ‘10’) for the Reader#1 (i.e. the built-in
reader). Cardholders are granted access only during the Time Intervals of the Time
Schedule code entered to this TA field. To set the Time Intervals for each Time Schedule
code, refer to the instructions on the Time Schedule Setup in the [F4 SETUP MENU]. If
you want allow the cardholder access to the door anytime, then enter the default Time
Schedule code '00' for the value.
5. TB – refers to the Time Schedule code (‘00’ ~ ‘10’) for the Reader#2 (i.e. Exit Reader).
Cardholders are granted access only during the Time Intervals of the Time Schedule code
entered to this TB field. To set the Time Intervals for each Time Schedule code, refer to the
instructions on the Time Schedule Setup in the [F4 SETUP MENU]. If you want allow the
cardholder access to the door anytime, then enter the default Time Schedule code '00' for
the value.
6. RD – refers to the Reader Assignment code for the cardholder. Entering the code ‘0’
assigns both readers (Built-in Reader and Exit Reader) to grant access to the user that is
being registered, code ‘1’ only assigns Reader#1 (Built-in Reader) and code ‘2’ assigns
Reader#2 (Exit Reader). If you enter ‘1’ in the RD field(Only Reader#1 assigned) and try to
exit through Reader#2 (Exit Reader) then LX505 generates an error message (“Access Door
Error”) on the LCD display.