A. THE RELATION BETWEEN INPUT AND OUTPUT (DEFAULT)
Default Output Settings for Input Sources
* Index No. [1] ~ [9]
The values indicate the operating time (second) of each output for the input signal.
* Index No. [10]
The values indicate the time schedule code (index) applied to each output operation.
* Index No. [11]
The values indicate the time schedule code (index) applied to each input from #1(Exit
button) to #5.
* Index No. [12]
The values indicate whether or not to use the cut off check feature.
(0 – NOT USE, 1 – USE)
* Index No. [12]
The values indicate whether the input type is NO(Normally Open) or NC(Normally Closed).
(0 – NO, 1 – NC)
OUTPUT
Door
Relay
(DR)
Alarm
Relay
(AR)
TTL#1
(T1)
TTL#2
(T2)
Buzzer
(BZ)
[1] EXIT BUTTON
03 00 00 00 00
[2] DOOR CONTACT
00 99 00 00 00
[3] AUX Input #1
00 00 00 00 00
[4] AUX Input #2
00 00 00 00 00
[5] TAMPER ALARM
00 99 99 99 99
[6] CUT OFF ALARM
00 00 00 00 00
[7] DURESS ALARM
00 00 00 00 00
[8] ARM/DISARM OUT
00 00 00 00 00
[9] DR TIME OUT
00 00 00 00 00
[10] OUTPUT TIME SCHEDULE
00 00 00 00 00
[11] INPUT TIME SCHEDULE
00 00 00 00 00
[12] CUT OFF CHECK
00 00 00 00 00
[13] INPUT TYPE
00 00 00 00 00