User Manual

- 10 -
7.4 OUTPUT CONFIGURATION CHANGE
- OUTPUT CONFIGURATION CHANGE when User ID is granted
(Master RFID)+(21)+(ENT)+(oo)+(ENT)
+(t1)+(ENT)+(t2)+(ENT)+(t3)+(ENT)+(t4)+(ENT)+(t5)+(ENT)
oo = Output numbers
t1 = OUTPUT RELAY#1 activate time
t2 = OUTPUT RELAY#2 activate time
t3 = TTL OUTPUT activate time
t4 = GREEN LED activate time
t5 = BUZZER activate time
Note: Output numbers(add all numbers below which you want to activate)
1 ...activate OUTPUT RELAY#1
2 ...activate OUTPUT RELAY#2
4 ...activate TTL OUTPUT
8 ...activate BUZZER
16 …activate GREEN LED
50 …activate on SAFE MODE
EX) If you want RELAY#1 and GREEN LED activate then 1+8+50=59 as output numbers
and you put "59" for (oo) format.
Activate time for t1 through t4 is "00" to "99" seconds.
EX) If you put "03" for t1 then OUTPUT RELAY#1 will activates for 3 seconds.
- OUTPUT CONFIGURATION CHANGE when User ID is denied
(Master RFID)+(22)+(ENT)+(oo)+(ENT)
+(t1)+(ENT)+(t2)+(ENT)+(t3)+(ENT)+(t4)+(ENT)+(t5)+(ENT)
EX) If you want OUTPUT RELAY#2 activate then 2+50=52 as output numbers
and you put "52" for (oo) format.
Activate time for t1 through t4 is "00" to "99" seconds.