Technical Specifications

#61-025
VoltAware™ Non-Contact Voltage (NCV)Tester
Instruction Sheet
IMPORTANT SAFETY INFORMATION
Read and understand all of the instructions and safety information in these operating instructions before
using this tester.
WARNINGS
To avoid possible electric shock, personal injury or death follow these guidelines:
• Donotuseifgreenlightisnotilluminatingontester.
• Donotuseiftesterappearsdamagedorisnotoperatingproperly.
• Donotusetesterformorethantheratedvoltageonthetester.
• Donotusewithoutthetesterfullyassembled.
• ThistesterwillnotdetectthepresenceofDCvoltage.
• Thistesterwillnotdetectvoltagesatadistance,suchasthroughwalls,metalconduit,or
shielded wire.
• Voltagedetectionmaybeaffectedbyoutletdesign,insulationthickness/type.
• Donotassumethatnovoltageindicationmeansthecircuitisde-energized.
• Voltagesbelow40VACwillnotbedetectedbythe61-025butarestillshockhazards
that can result in injury or death.
• Usethe3PointSafetyMethod.(1)Verifytesteroperationbymeasuringaknownvoltage.(2)Applytestertocircuitundertest.(3)Returnto
the known live voltage again to ensure proper operation.
• Ensureallngersarebehindngerguardwhentestingforvoltage.
• IfthistesterisusedinamannernotspeciedbyIDEAL,protectionprovidedbytheproductmaybeimpaired.
• Complywithlocalandnationalsafetyrequirements,includingtheuseofappropriatepersonalprotectiveequipment.
Features:
TheVoltAware™NCVtesterisusefulforidentifyinghotconductors,ndingbreaksinwiresanddetectingthepresenceofACvoltageatoutlets,
switches, electrical panels, wires and cables.
• 61-025modelindicatespresenceofvoltagefrom40-1000VAC
• Visualindicationofvoltage
• SelectableAudibleindicationofvoltage
• LowBatteryIndicator
• Sleek,compactdesign
Operation:
• TwistthetesterbodytotheOnposition.
• Verifythegreenlightison.
• Verifytesteroperationonaknownvoltagesource.
• PlacethetipofthetesternearanACvoltagesourcetoobtainavoltageindication.
• Voltagepresenceisindicatedbyared,ashinglight.
Selectable On/Off for Audible Beeper:
• ThetesterdefaultstotheaudibleONmode.
• ToturntheaudibleOff,depressthedarkgraybutton.
• ToturntheaudiblebackOn,depressthebuttonagain.
Note:Testermustbeinstandbymodeforbuttontoactivatecircuitry.
Low Battery Indicator:
• Whenthebatteryvoltagedropsbelow2V,thetesterindicatesthelowbatteryconditionby
turning off the green light.
Battery Replacement:
• Withthetesterinthemiddleposition,pullapartthetwocasehalves.
• Replacewith2AAA(LR03)batteries.
• Reverseprocesstore-assembletester.
Maintenance:
Cleanwithadampclothandmilddetergent.Ifthetesteractserratically,orthegreenlightisnoton,
change the batteries.
Service and Replacement Parts:
Therearenouser-serviceableparts.Toinquireaboutserviceinformation,contactIDEAL
INDUSTRIES,INC.at877-201-9005,orvisitourwebsiteatwww.testersandmeters.com.
Specifications:
Voltage Range:
40-1000VAC(61-025)
Frequency Range:
50-500Hz
Operating Environment:
32to122°F(0to51°C)at<95%R.H.
Storage Temp.:
-4to140°F(-20to60°C)at<95%R.H.
Battery:
(2)1.5VAAAbatteries(IECLR03)
Altitude:
9843ft.(3000m)
Dimensions:
6.0”(H)x0.75”(D)[152mm(L)x19mm(D)]
Weight:
1.6oz.(46g)
Safety
ComplieswithUL-61010,EN61010,CatIV-1000V
Equipment protected by double insulation.
InstrumentcomplieswithinsulationovervoltagecategoryIV.CatIVequipmentisdesignedtoprotectagainsttransientsfromprimarysupply
level.Pollutiondegree2inaccordancewithIEC-664.Indooruse
OFF
ON
#6
1
-
025
Cat IV 40-1000VAC
OFF
ON
#
61-025
4
0-1000VAC
N12966

Summary of content (4 pages)