Gas hob IZGS980ITX
CONTENTS Safety information Installation Product description Operating instructions Helpful hints and tips 2 4 7 7 8 Care and cleaning What to do if… Technical data Environment concerns 8 9 10 11 Subject to change without notice SAFETY INFORMATION Warning! These instructions are only valid in the countries whose symbols appear on this booklet's cover. For your safety and correct operation of the appliance, read this manual carefully before installation and use.
Installation • You must read these instructions. The manufacturer is not responsible for any injury to persons and pets or damage to property caused by failure to obey these requirements. • To prevent the risks of structural damage or physical injury, installation, connection of the appliance to the power supply and gas system, setting up and maintenance must only be done by qualified personnel in compliance with standards and local regulation force.
• You must have correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), ground leakage trips and contactors. Disposal of the appliance • To prevent the risk of physical injury or damage – Disconnect the appliance from the power supply. – Cut off the mains cable where it connects with the appliance and discard it. – Flat the external gas pipes if there are fitted. – Speak to your local authorised facilities for disposal of your appliance.
you use (see table in Technical Data section). 4. Assemble the parts, follow the same procedure backwards. 5. Replace the rating label (it is near the gas supply pipe) with the one for the new type of gas supply. You can find this label in the package of the injectors supplied with the appliance. If the supply gas pressure is changeable or different from the necessary pressure, you must fit an applicable pressure adjuster on the gas supply pipe.
Building In case a technical assistance intervention is necessary. 30 mm min. 150 mm min. 650 mm min. 55 mm 480 mm 30 mm A 27 mm 3 mm min 20 mm (max 150 mm) b 830 mm 10 mm a 60 mm 27 mm a) Removable panel b) Space for connections Kitchen unit with oven The hob recess dimensions must obey the indication and the kitchen unit must be equipped with vents to let a continuous supply of air.
PRODUCT DESCRIPTION Cooking surface layout 1 2 3 5 1 2 3 4 5 Auxiliary burner Semi-rapid burner Triple Crown burner Control knobs Rapid burner 4 Control knobs Symbol Symbol Description Description ignition position / maximum gas supply no gas supply / off position minimum gas supply OPERATING INSTRUCTIONS Ignition of the burner Warning! Be very careful when you use open fire in kitchen environment.
Warning! If the burner does not light after 15 seconds, release the control knob, turn it into off position and try to light the burner again after minimum 1 minute. Important! In the absence of electricity you can ignite the burner without electrical device; in this case approach the burner with a flame, push the relevant knob down and turn it counter-clockwise to maximum gas release position.
• Make sure you position the pan supports correctly after cleaning. • To make burners work correctly, make sure that the arms of the pan supports are in the centre of the burner. • Be very careful when you replace the pan supports to prevent the hob top from damage. After cleaning, dry the appliance with a soft cloth. The stainless steel can become tarnished if it is too much heated. Refer to this you must not cook with potstones, earthenware pans or cast iron plates.
If there is a fault, first try to find a solution to the problem yourself. If you cannot find a solution to the problem yourself, speak your dealer or the local Service Force Centre. If you operated the appliance incorrectly, or the installation was not carried out by a registered engineer, the visit from the customer service technician 1 or dealer may not take place free of charge, even during the warranty period.
By-pass diameters Burner Burner Ø By-pass in 1/100 mm Ø By-pass in 1/100 mm Rapid 42 Auxiliary 28 Triple Crown 56 Semi-rapid 32 Gas burners NORMAL POWER NORMAL POWER REDUCED POWER kW kW inj. 1/100 mm m³/h inj. 1/100 mm G30 G31 g/h g/h Auxiliary burner 1.0 0.33 70 0.095 50 73 71 Semi-rapid burner 2.0 0.45 96 0.190 71 145 143 Rapid burner 3.0 (natural gas) 2.8 (LPG) 0.75 119 0.286 86 204 200 Triple Crown burner 4.0 1.4 146 0.