Install Instructions

UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS
The combinations listed are Cu-Cu Only. (Do Not use on Al-Al connections.)
The combinations listed are solid and/or stranded wire unless otherwise noted.
UL File No. E5238
Model 600 Volt Maximum
32
#12 to #20 Sol.
33
#12 to #16 Str. (≤ 19 Str.)
34
#18 Str. (7 Str.)
#14 to #18 Str. Tin-bonded (≤ 19 Str.)
Model 600 Volt Maximum
#10 to #14 Sol.
39
#10 to #12 Str. (≤ 19 Str.)
#10 to #14 Str. Tin-bonded (≤ 19 Str.)
Model 600 Volt Maximum
#12 to #20 Sol.
42
#12 to #16 Str. (≤ 19 Str.)
#14 to #18 Str. Tin-bonded (≤ 19 Str.)
Model 600 Volt Maximum
1 or 2 #14 1 #14 w/1 #16
2 #16 w/1 to 3 #22 2 #18 w/1 or 2 #22 or #20
1 #16 Str. 1 #14 w/1 #16 w/1 #18
2 #16 w/1 or 2 #20 1 #18 w/2 to 4 #20
61
2 #16
1 #14 w/1 or 2 #18 1 #16 w/1 or 2 #18 1 #18 w/3 or 4 #22
1 to 4 # 18 Str.
1 #14 w/1 to 3 #20 1 #16 w/1 to 3 #20 1 or 2 #16 w/1 #20 w/1 #22
2 to 4 #18 Sol.
1 # 14 w/1 to 3 #22 1 #16 w/1 to 3 #22 1 or 2 #18 w/1 #20 w/1 #22
2 to 4 #20
2 #16 w/1 #18 3 #18 w/1 #22 or #20
Model 600 Volt Maximum
2 to 6 #18 1 to 4 #12 Sol. 2 #18 w/1 to 4 #16 or #14 1 #12 w/1 or 2 #10
62
1 to 6 #16 1 to 3#10 1 #14 w/1 to 3 #12 1 #12 w/1 #8
1 to 5 #14 1 #18 w/1 to 4 #16, #14 or #12 1 #14 w/1 or 2 #10 1 #10 w/1 #8
1 to 3 #12 1 #18 w/1 or 2 #10 2 #14 w/1 or 2 #12 or #10
Model 600 Volt Maximum
3 to 6 #14 1 #16 w/2 to 5 #14 or #12 1 #14 w/1 or 2 #8 3 #12 w/1 #10 or #8
63
2 to 6 #12 1 #16 w/1 to 3 #10 1 #12 w/1 or 2 #10 1 #10 w/1 or 2 #8
2 to 5 #10 1 #14 w/3 or 4 #12 1 #12 w/1 or 2 #8 1 #8 w/1 #6
1 or 2 #8 1 #14 w/1 to 3 #10 1 or 2 #12 w/1 #6
Model 600 Volt Maximum
1 or 2 #10 2 #14 w/1 #12 2 #16 w/1 to 4 #14 1 #18 w/1 to 3 #12, #14 or #16
1 to 3 #12 3 #14 w/1 #12 3 #16 w/1 to 3 #14 2 #18 w/1 or 2 #10
1 #12 w/1 #8 1 #16 w/2 #10 3 #16 w/1 or 2 #10 or #12 2 #18 w/1 or 2 #12, #14 or #16
60
1 #12 w/1 #10 1 #16 w/1 to 3 #12 or #14 3 #16 w/1 #14 w/1 #10 or #12 3 #18 w/1 or 2 #10
2 #12 w/1 #10 1 #16 w/1 #10 or #12 w/1 or 2 #14 4 #16 w/1 or 2 #12 or # 14 3 #18 w/1 or 2 #14 or #16
1 to 4 #14 2 #16 w/1 or 2 #12 4 #16 w/1 #10 w/1 #12 3 #18 w/1 #10
1 #14 Sol. w/1 to 2 #12 2 #16 w/1 #12 w/1 #14 4 #16 w/1 #10 1 #20 w/1 to 4 #16 or #18
1 #14 w/1 or 2 #10 2 #16 w/1 or 2 #14 5 #16 w/1 #14 2 #20 w/1 to 3 #14, #16 or #18
2 #14 w/1 #10 2 #16 w/1 #10 5 #16 Sol. w/1 #10 Sol.
Model 600 Volt Maximum
3 or 4 #22 Sol. 2 to 4 #14 1 #18 w/1 to 4 #16, #14 or #12 2 #14 w/1 #12 or #10
64
3 or 4 #20 Sol. 1 to 3 #12 1 #16 w/1 to 4 #14 or #12 2 #12 w/1 #10
2 to 4 #18 1 to 3 #10 1 #14 w/1 or 2 #12 or #10 1 #8 w/1 #14, #12 or #10
2 to 4 #16
Model 600 Volt Maximum
1 or 2 #6 2 #6 w/1 #10 2 #8 w/1 to 4 #14 3 #10 w/1 to 3 #14
2 or 3 #8 2 #6 w/1 #12 3 #8 w/1 or 2 #14 4 #10 w/1 or 2 #12
2 to 5 #10 2 #6 w/1 or 2 #14 1 #10 w/2 to 4 #12 4 #10 w/1 or 2 #14
66
3 to 6 #12 1 #8 w/1 to 4 #10 1 #10 w/3 to 5 #14 1 #12 w/4 or 5 #14
1 #6 w/1 or 2 #8 1 #8 w/1 to 5 #12
2 #10 w/1 to 4 #12
2 #12 w/2 to 4 #14
1 #6 w/1 to 3 #10 1 #8 w/1 to 5 #14
2 #10 w/1 to 4 #14
3 #12 w/1 to 3 #14
1 #6 w/1 to 5 #12 2 #8 w/1 or 2 #10 3 #10 w/1 to 3 #12 4 #12 w/1 #14
1 #6 w/1 to 4 #14 2 #8 w/1 to 3 #12
Model
Line Side
Ballast Side
Electrical Rating
102
#12 to #18 Sol.
#18 Sol.
6Amps / 600Volts Max.
&
#12 to #14 Str. (≤ 19 Str.)
#18 Str. (7 Str.)
103
#18 Str. (7 Str.) #18 Str. Tin-bonded (≤ 16 Str.)
#12 to #14 Str. Tin-bonded (≤ 19 Str.)
#16 Str. Tin-bonded (≤ 26 Str.)
#18 Str. Tin-bonded (≤ 16 Str.)
Model
Line Side Ballast Side
Electrical Ratings
182
#18 Sol. #18 Sol.
3 Amps / 120 Volts
&
1.3 Amps / 277 Volts
183
1 Amps / 347 Volts
0.75 Amps / 480 Volts
0.60 Amps / 600 Volts
IDEAL PowerPlug® Luminaire Disconnects
IDEAL In-Sure® Push-In Wire Connectors
IDEAL SpliceLine™ Wire Connector
IDEAL WeatherProof™ Wire Connectors
IDEAL UnderGround™ Wire Connectors
Page 5 Revised 05/07/10