Instructions / Assembly

87
AC Voltage
Range Resolution Max Accuracy
Display
2000mV 1mV 1999 ±(1.2%+3)
200V 0.1V 199.9 ±(1.2%+3)
750V 1V 750 ±(2%+5)
Frequencyresponse:50Hz-500Hz;±(2%+5)500Hz-1KHz;
50Hz-500Hzon600Vand750Vranges.
TrueRMSSensing:(61-704only)
To Measure AC Current:
1. Set the rotary switch to the appropriate AAC range.
2. With the jaws closed, separate one wire from a bundle using
the long fixed jaw.
3. Slide the wire to the corner where the two jaws meet, then
open the jaws to let it in.
4. Measure the current in only one wire at a time.
AC & DC Volts
DC Voltage
Range Resolution Max Accuracy
Display
2000mV 1mV 1999 ±(0.5%+1)
200V 0.1V 199.9 ±(0.5%+1)
1000V 1V 1000 ±(0.5%+1)
To Measure Voltage:
5. Plug the black test lead into the COM port and the red test
lead into the + port.
6. Set the rotary switch to appropriate VAC or VDC range.
7. Connect the meter in parallel with the load or circuit.
8. Measure the voltage
Frequency
To Measure Frequency:
1. Plug the black test lead into the COM port and the red test
lead into the + port.
2. Set the rotary switch to the HZ position.
3. Connect the meter in parallel with the load or circuit.
4. Meterisauto-ranging,andwillselect2k20kor40krange.
5. Measure the frequency.