Full Product Manual
Form number TM61763-5 Rev 4 July 2010
Page 3
Certifications and Compliances
Safety
Designed to UL 61010-1 second edition, IEC 61010-2-032 second
edition,IEC61010-031 specifications
Input rating
1000V DC Category III
600V DC Category IV
750V AC Category III
600V AC Category IV
Over voltage category
CAT IV: Outside and service entrance.
CAT III: Distribution level mains, fixed installation.
CAT II: Local level mains, appliances, and portable equipment.
CAT I: Signal level, special equipment or parts of
equipment, telecommunication, electronics.
General Specifications
Characteristics
Description
Display
4 Digit LCD display
Display Count
9999 count, maximum reading 9999
Over range Indication
“OL” is displayed
Sampling Rate
2.0 time/second
Operating
Relative Humidity
0 C to 50 C (32 F to 122 F)
0 ~ 70% RH
Storage Environment:
-20 C to 60 C (-4 F to 140 F) at <80% relative humidity
Power source:
9V Battery (NEDA 1604)
Battery Life:
100 hours typical (alkaline) {61-763}
100 hours typical (alkaline) {61-765}
Low Battery Indicator:
symbol indicates low battery voltage
Auto power off
Approximately 30 minutes
Dimensions
8.7” H X 3.1 ” W X 1.8 ” D
222mm H X 80mm W X 45.5mm D
Maximum Cable Size
ACA 1¼” (36mm)
Weight:
Approximately 12.4 oz. or 350g including battery
RANGES and ACCURACY SPECIFICATION
Accuracy: Accuracy specifications at 23°C ±5°C (73.4°F ±9°F) less than 75% RH.
Temperature Coefficient: 0.1 times the applicable accuracy specification per degree C
from 0 C to 18 C and 28 C to 50 C (32 F to 64 F and 82 F to 122 F)
Electrical Specification: Accuracy are ±(reading plus number of digits) at 23°C ±5°C
(73.4°F ±9°F) <75% RH