3 4
Features
1. Taperedjawsw/hooktip
2. Lever
3. FunctionDial
4. MainDisplay(LCD)
5. Voltsandresistance(V-Ω)
input terminal
6. Common(COM)inputterminal
7. TightSight
®
bottom display
8. Protective rubber boot
9. MeasuringFunctions
10. HighVoltage(Hi-V)warning
11. Data&PeakHold
12. Max/min
13. Relative(61-763,61-773)
Relative/Zero(61-765,61-775)
14. Backlight
15. Capacitance()/Frequency(Hz)
16. Tactilebarrier
Common Features:
1
10
3
15
4
5
9
16
12
13
14
6
8
7
2
APO HOLD MAX MIN P
+
P -
mVA
nm F
kM
Hz
AC
DC
Main Display Icons
17. 9999countdisplay
18. ACmeasurement
19. DCmeasurement
20. PolarityindicatorforDC
21. AutoPowerOff
(APO)
22. Hold
23. Min/Max
24. Peak
25. Audible continuity
26. Relative
27. Volts/Amps
28. Farads
29.Hertz/Ohms
30. Lowbatteryindicator
TightSight
®
Display Icons
31. 9999countdisplay
32. PolarityindicatorforDC
33. DCmeasurement
34. ACmeasurement
35. Amps
Main Display
DCAC AMPS
32
31
33 34 35
27
30
26
28
29
25
2223 24
Symbols on the Unit
11
17
18
19
20
21
RiskofDanger.ImportantInformation.SeeManual.
Hazardousvoltage.Riskofelectricalshock.
ApplicationaroundandremovalfromHazardousLiveconductorsispermitted.
AC(AlternatingCurrent)
DC(DirectCurrent)
Earth Ground
CAT II
MeasurementCategoryIIappliestotestandmeasuringcircuitsconnecteddirectlytoutilization
points(socketoutletsandsimilarpoints)ofthelow-voltageinstallation
CAT III
MeasurementCategoryIIIappliestomeasuringcircuitsconnectedtothedistributionpartofthe
building’slow-voltageinstallation
CAT IV
MeasurementCategoryIVappliestotestandmeasuringcircuitsconnectedatthesourceofthe
building’slow-voltageinstallation
~
...
•Largenumbersandsymbolsdisplayed
•TightSight
®
bottom display
•Visualandselectableaudibleindication
when voltage is present
•MeasuresAC/DCVoltage,Resistance&
Capacitance
•Audiblecontinuity
•Bright,boldbacklight
•Peak,max/min,datahold
•SelectableAutopoweroffandlowbattery
indicator
•Taperedjawsforreachingintotightspaces
•Hooktipforeasierwireseparation
•Protectiverubberboot
•Electronicoverloadprotectiononall
ranges
•CatIV-600V/CatIII-1000V
•AllmodelsemployaHighFrequency
Reject(HFR)circuittofilternoiseor
help in making accurate measurements
oncomplexwaveshapeslikethose
foundonAdjustableSpeedDrives
(ASDs)
Model Specific Features:
•61-763:660AAC • 61-773:1000AAC