RANGES and ACCURACY SPECIFICATION
Measurement Characteristics
(All at 75°F ± 5°C, < 85% R.H.)
Ground Resistance
Range Measuring Range Resolution Accuracy
20Ω 0.00Ω - 20.99Ω 0.01 Ω ± 1.5% ± 0.05Ω
16.0Ω - 99.9Ω 0.1Ω ± 2% ± 0.5Ω 200Ω
100.0Ω - 209.9Ω 0.1Ω ± 3% ± 2Ω
160Ω - 399Ω 1Ω ± 5.0% ± 5Ω
400Ω - 599Ω 1Ω ± 10.0% ± 10Ω
1200Ω
600Ω - 1260Ω 10Ω
Unspecified
Continuity Measurement: Beep if resistance < 10.00 Ω (approximately)
Ground/Leakage Current
Range Measuring Range Resolution Accuracy
100mA 0.0 - 104.9mA .1mA
± 2.0% ± 0.7mA
1000mA 80 - 1049mA 1mA
± 2.0%
10A 0.80 - 10.49A .01A
± 2.0%
30A 8.0 - 31.5A .1A
± 2.0%
*Crest factor 2.5 accuracy at sine wave +1% (50Hz/60Hz, peak value shall not exceed 60A)
*In the following case, ZERO will be displayed on the LCD
At 20 Ω range if Earth resistance measured is 0.04 Ω
*Auto ranging shifts to upper range when the input exceeds 105% of the selected range, and shifts to the lower
range when the input falls under 80% of the lower range.
Form number TM61920 Rev 4 July 2008