SDS

Material Safety Data Sheet
Report No.:STR14109087S Page 4 of 10
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
victim is rapidly losing consciousness, or is unconscious or convulsing. Have victim
rinse mouth thoroughly with water. DO NOT INDUCE VOMITING. Have victim
drink 60 to 240 mL (2-8 oz.) of water. If vomiting occurs naturally, have victim lean
forward to reduce risk of aspiration. Have victim rinse mouth with water again.
Quickly transport victim to an emergency care facility.
Section 5 – Fire-fighting Measures
Flammable
Properties
In the event that this battery has been ruptured, the electrolyte solution contain
within the battery would be flammable. Like any sealed container, battery cells may
rupture when exposed to excessive heat; this could result in the release of
flammable or corrosive materials.
Suitable
extinguishing
Media
Use extinguishing media suitable for the materials that are burning.
Unsuitable
extinguishing
Media
Not available
Explosion
Data
Sensitivity to Mechanical Impact: This may result in rupture in extreme cases
Sensitivity to Static Discharge: Not Applicable
Specific
Hazards
arising from
the chemical
Fires involving Alkaline Battery an be controlled with water. When water is used,
however, hydrogen gas may evolve. In a confined space, hydrogen gas can form
an explosive mixture. In this situation, smothering agents are recommended to
extinguish the fire
Protective
Equipment
and
precautions
for firefighters
As for any fire, evacuate the area and fight the fire from a safe distance. Wear a
pressure-demand, self-contained breathing apparatus and full protective gear.
Fight fire from a protected location or a safe distance. Use NIOSH/MSHA approved
full-face self-contained breathing apparatus (SCBA) with full protective gear.
NFPA Health: 0 Flammability: 0 Instability: 0
Section 6 – Accidental Release Measures
Personal Precautions, protective equipment, and
emergency procedures
Restrict access to area until completion of
clean-up. Do not touch the spilled material. Wear
adequate personal protective equipment as
indicated in Section 8.
Environmental Precautions Prevent material from contaminating soil and
from entering sewers or waterways.
Methods and materials for Containment Stop the leak if safe to do so. Contain the spilled
liquid with dry sand or earth. Clean up spills