Instructions / Assembly

1) Use coax stripper to strip
cable so ¼” of conductor
and ¼” of braiding are
exposed. (45-605 shown)
3) Center cable over back end of
connector and push connector on
to cable until fully seated.
Dielectric flush with bottom of nut.
2) Fold back braiding, make sure
no braids are touching the
center conductor. Straighten
conductor if needed. Do not
remove foil that is attached to
the white dielectric (RG6/6Q)
5) Place assembly in appropriate
crimp tool cavity (30-503 shown)
and crimp.
6) Verify connector is fully crimped
and the body is not cracked or
pinched from incorrect tool cavity
being used.
©2016 IDEAL INDUSTRIES, INC
IDEAL F Crimp Termination Instructions
RG6 coax is used in this example. General preparation instructions are the same for all IDEAL F crimp
connectors. When working with RG6 Quad cable, the outer foil can be removed, and the inner braiding
should be folded down. This makes it easier to push the connector on to the cable. For IDEAL F crimp
connectors, RG6 and RG59 use the middle cavity of the 30-503 tool (.320” hex). The RG6 Quad F uses the
largest cavity (.350” hex)
4) When crimping the connector,
only crimp the areas below the
shoulder ring.
Crimp
Zone
NO
Crimp
Zone
Inside
crimping
cavity
Outside
crimping
cavity
SHOULDER

Summary of content (1 pages)