Datasheet

www.apem-idec.eu
D-021
ø16 XA Series Emergency Stop Switches Round Form (w/Removable Contact Blocks)
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Emergency Stop Switches
X6
XA
XW
XN
SEMI
Smooth Round Form Buttons
IDEC's unique Reverse Energy Structure
Depth behind the panel: 27.9mm
Arrow marked and unmarked buttons.
The smooth button is ideal for applications that require utmost
cleanliness.Prevents dust built-up, and is also easy to clean.
Two reset operations - pushlock pull or turn reset.
Silver with gold contacts.
Direct opening action (IEC60947-5-5:5.2, IEC60947-5-1, Annex K)
Safety lock mechanism (IEC60947-5-5:6.2)
Degree of protection IP65 (IEC60529)
Terminal Cover
(XA9Z-VL2)
LED Unit
Contact Ratings
NC main contacts (black) /NO monitor contact (blue)
Rated Insulation Voltage (Ui) 300V (illuminated part: 60V)
Rated Thermal Current (Ith) 5A
Rated Operating Voltage (Ue) 30V 125V 250V
Rated Operating Current
Main
Contacts
AC
50/60
Hz
Resistive Load
(AC-12)
3A 3A
Inductive Load
(AC-15)
1.5A 1.5A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
Monitor
Contacts
AC
50/60
Hz
Resistive Load
(AC-12)
1.2A 0.6A
Inductive Load
(AC-14)
0.6A 0.3A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
• Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(Operating area may vary according to the operating conditions and load
types.)
• The rated operating currents are measured at resistive/inductive load types
specied in IEC 60947-5-1.
Illumination Ratings
Rated Voltage Operating Voltage Rated Current
24V AC/DC 24V AC/DC ±10% 11 mA
Specifications
Applicable Standards
IEC60947-5-1, EN60947-5-1
IEC60947-5-5, EN60947-5-5, JIS C8201-5-1, UL991,
NFPA79, UL508, CSA C22.2 No.14, GB14048.5
Operating
Temperature
–25 to +60°C (no freezing)
Illuminated: –25 to +55°C (no freezing)
Storage Temperature –45 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Operating Force
Push to lock: 10.5N
Pull to reset: 10N
Turn to reset: 0.16 N·m
Minimum Force
Required for Direct
Opening Action
60N
Minimum Operator
Stroke Required for
Direct Opening Action
4.0 mm
Maximum Operator
Stroke
4.5 mm
Contact Resistance
50 mΩ maximum (initial value)
Insulation Resistance
100 MΩ minimum (500V DC megger)
Overvoltage Category II
Impulse Withstand
Voltage
2.5 kV
Pollution Degree 3 (inside LED unit: 2)
Operation Frequency 900 operations/hour
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes: 10 to 500 Hz, amplitude 0.35 mm,
acceleration 50 m/s
2
Damage limits: 10 to 500 Hz, amplitude 0.35 mm,
acceleration 50 m/s
2
Mechanical Life 250,000 operations minimum
Electrical Life
100,000 operations min
250,000 operations min (24V AC/DC, 100 mA)
Degree of Protection IP65 (IEC60529)
Short-circuit
Protection
250V/10A fuse
(Type aM, IEC60269-1/IEC60269-2)
Conditional
Short-circuit Current
1000A
Terminal Style Solder terminal, PC board terminal
Recommended
Tightening Torque
for Locking Ring
0.88 N·m
Connectable Wire 1.25 mm
2
maximum (AWG16 maximum)
Soldering Conditions 310 to 350°C, 3 seconds maximum
Weight ø30 mm: 23g, ø40 mm: 28g
Standards and Specications