Datasheet

www.apem-idec.eu
D-026
ø22 XW Series Emergency Stop Switches
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Emergency Stop Switches
X6
XA
XW
XN
SEMI
ø22 mm, 4-contact Emergency Stop Switch. Compact size—only 37.1 mm deep behind the panel
(screw terminal style 48.7 mm with terminal cover). Reliable “Safe break action.”
Standards and Specications
Contact Ratings
(NC main contacts/NO monitor contact)
Rated Insulation
Voltage (Ui)
Screw Terminal 250V
Solder Terminal
300V
PC Board Terminal
Connector
125V
Rated Thermal Current (Ith) 5A (connector style: 2.5A)
Rated Operating Voltage
(Ue)
30V 125V
250V
(Note 3)
Rated Operating Current
Main
Contacts
AC
50/60 Hz
Resistive Load (AC-12)
5A
(Note 1)
3A
Inductive Load (AC-15)
3A
(Note 2)
1.5A
DC
Resistive Load (DC-12) 2A 0.4A 0.2A
Inductive Load (DC-13) 1A 0.22A 0.1A
Monitor
Contacts
AC
50/60 Hz
Resistive Load (AC-12) 1.2A 0.6A
Inductive Load (AC-14) 0.6A 0.3A
DC
Resistive Load (DC-12) 2A 0.4A 0.2A
Inductive Load (DC-13) 1A 0.22A 0.1A
• Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(Operating area depends on the operating conditions and load types.)
• The rated operating currents are measured at resistive/inductive load types
specied in JIS C8201-5-1.
Note 1: Solder terminal/PC board terminal: 3A, Connector: 2.5A
Note 2: Solder terminal/PC board terminal: 1.5A
Note 3: Except for connector style.
Illumination Ratings
Rated Voltage Operating Voltage Rated Current
24V AC/DC 24V AC/DC ±10% 15 mA
Note: An LED lamp is built into the contact block and cannot be replaced.
Specifications
Applicable Standards
IEC60947-5-1, EN60947-5-1
IEC60947-5-5 (Note), EN60947-5-5
JIS C8201-5-1, UL508, UL991, NFPA79,
CSA C22.2 No. 14, GB14048.5
Operating Temperature
Non-illuminated: –25 to +60°C (no freezing)
LED illuminated: –25 to +55°C (no freezing)
Storage Temperature –45 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Operating Force
Push to lock: 32N
Pull to reset: 21N
Turn to reset: 0.27 N·m
Minimum Force Required
for Direct Opening Action
80N
Minimum Operator Stroke
Required for Direct
Opening Action
4.0 mm
Maximum Operator Stroke 4.5 mm
Contact Resistance
50 mΩ maximum (initial value)
Connector style: 30 mΩ (Note)
Insulation Resistance
100 MΩ minimum (500V DC megger)
Overvoltage Category II
Impulse Withstand Voltage 2.5 kV
Pollution Degree 3 (connector style: 2)
Operation Frequency 900 operations/hour
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes: 10 to 500 Hz, amplitude 0.35 mm,
acceleration 50 m/s
2
Damage limits: 10 to 500 Hz, amplitude 0.35 mm,
acceleration 50 m/s
2
Mechanical Life 250,000 operations minimum
Electrical Life
100,000 operations minimum
250,000 operations minimum (24V AC/DC, 100 mA)
Degree of Protection
Panel front: IP65, IP67 (IEC 60529)
Terminal Protection: IP20 (screw terminal, when using XW9Z-VL2MF)
Short-circuit Protection
250V/10A fuse (Type aM, IEC60269-1/IEC60269-2)
Conditional
Short-circuit Current
1000A
Terminal Style
Solder terminal, PC board terminal,
M3 screw terminal, Connector
Recommended
Tightening Torque for
Locking Ring
2.0 N·m
Connectable Wire
Screw terminal: 0.75 to 1.25 mm
2
(AWG18 to 16)
Solder terminal / PC board terminal:
1.25 mm
2
maximum (AWG16 maximum)
Connector style: 0.3 to 0.85 mm
2
(AWG22 to 18)
Soldering Conditions 310 to 350°C, 3 seconds maximum
Recommended
Tightening Torque for
Terminal Screw
0.6 to 1.0 N·m
Weight ø40 mm: 72g ø60 mm: 81g
Note: When connecting the applicable connector to a 1m wire of 0.3 mm
2
(AWG22).
The depth behind the panel is only 37.1 mm for 1 to 4 contacts
(screw terminal style 48.7 mm with terminal cover).
• The same depth behind the panel for illuminated and non-illuminated switches.
IDEC’s original “Safe break action” ensures that the contacts open
when the contact block is detached from the operator.
1 to 4NC main contacts and 1 or 2NO monitor contact
Push-to-lock, Pull or Turn-to-reset operator
• Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K)
Safety lock mechanism (IEC60947-5-5, 6.2)
Degree of protection IP65, IP67 (IEC60529)
Durable, silver with gold contacts.
Screw terminal style is nger-safe (IP20).
Two operator sizes: ø40 and ø60 mm
Dark red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors
are available for the non-illuminated operator.
Push-ON illumination available (operator size: ø60)
Connector style available to reduce wiring time and wiring mistakes.
Direct Opening Action