Datasheet

www.apem-idec.eu www.apem-idec.eu
D-003 D-004
Emergency Stop Switches Selection Guide
IDEC’s original “Safe Break Action” and “Reverse
Energy Structure”ensure the safety of operator
and system, when the switch is damaged due to
excessive shocks.
International Safety Standards Requirements
Red-colored, mushroom actuator, with yellow background
(IEC 60947-5-5; 4.2, ISO 13850; 4.4, IEC 60204-1; 10.7)
Normally closed contacts with a direct opening action
(IEC 60947-5-5; 5.2, IEC 60947-5-1; Annex K)
The emergency stop function shall be maintained by latching of the
operator until reset manually
(IEC 60947-5-5; 6.2, ISO 13850; 4.4)
Third
Generation
Developed before the establishment
of international safety standards.
Compliant with international safety standards.
Compliant with international safety
standards. Even more consideration
has been taken into account on
operator safety.
Satisfies the requirements of:
Red-colored, mushroom actuator,
with yellow background
Direct opening action
Satisfies the requirements of:
Red-colored, mushroom actuator, with yellow background
Direct opening action
Safety lock mechanism
Satises the requirements of:
Red-colored, mushroom actuator,
with yellow background
Direct opening action
Safety lock mechanism
IDEC’s Unique
Reverse Energy Structure
Safe Break Action
Long Commited to providing the Highest Level of Safety
Third-
generation
Safety
Second
Generation
First
Generation