Datasheet

www.apem-idec.eu
D-036
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Emergency Stop Switches
X6
XA
XW
XN
SEMI
ø22 XW Series Emergency Stop Switches
Instructions
About PC Board and Circuit Design
1. Use PC boards made of glass epoxy copper-clad lami nated sheets of
1.6 mm in thickness, with double-sided through hole.
2. PC boards and circuits must withstand rated voltage and current,
including the instantaneous current and voltage at switching.
3. The minimum applicable load is 5V AC/DC, 1 mA. This value may
vary according to the operating environment and load.
4. Within the 2.8 mm areas shown in the figure below, ter minals
touch the PC board, resulting in possible short cir cuit on the printed
circuit. When designing a PC board pattern, take this possibility into
consideration.
19.8
8.7
19.8
8.7
(0.5)
(0.5)
(0.5)
5.7
1.6 (PC Board)
(0.5)
(0.5)
2.8
2.8
2.8
(0.5)
2.8 2.8
10-ø1.2 holes
Solder
Surface
Solder Surface
Surface for installing
components
Surface for installing
components
Screw Terminal
Applicable Crimping Terminals Solid Wire
Wire
Insulating Tube
Crimping Terminal
4.7 to 5.9
6.0 max.
3.2 min.
4.7 to 5.9
3.0 max.
ø3.2 min.
Wire
Insulating Tube
Crimping
Terminal
4.7 to 5.9
ø6.0 max.
4.7 min.
6.2 max.
ø1.2 max.
Ring Terminal Spade Terminal
1. Wire thickness: 0.75 to 1.25 mm
2
(AWG18 to 16)
Be sure to install an insulating tube on the crimping terminal.
2. Tighten the M3 terminal screw to a tightening torque of 0.6 to 1.0
N·m.
Connector
1. Connector shape
Tyco Electronics, D-2000 series
Part No. 1376009-1 (tab header, board mount)
2. Applicable connectors (to be supplied by user)
Tyco Electronics, D-2000 series
Part No. 1-1318119-4 (receptacle housing)
Tyco Electronics, D-2000 series
Part No. 1318107-1 (receptacle contact)
3. To prepare correct receptacles for the connector, read the instruction
sheet and catalog of Tyco Electronics and understand the installation
and wiring method.
4. Fasten the cable so that the connector is not pulled.
Otherwise the switch may be deformed and damaged, causing mal-
function or operation failure.
Installing & Removing Terminal Covers
XA9Z-VL2 (Terminal Cover for Solder Terminals)
To install the terminal cover, align the TOP marking on the terminal
cover with TOP marking on the contact block, and press the terminal
cover toward the contact block.
Note: For wiring, insert the wires into the holes in the terminal cover before soldering.
XW9Z-VL2M (Terminal Cover for Screw Terminals)
To install the terminal cover, align the TOP marking on the terminal
cover with the TOP marking on the contact block. Place the two projec-
tions on the bottom side of the contact block into the slots in the termi-
nal cover. Press the terminal cover toward the contact block.
c
Place the projections
on the contact block
.
TOP marking
d Press the
terminal cover
To remove the terminal cover, pull out the two latches on the top side
of the terminal cover. Do not exert excessive force to the latches, other
-
wise the latches may break.
TOP markings
Pull out the latches.
XW9Z-VL2MF (IP20 Protection Terminal Cover)
To install the IP20 protection cover, align the TOP marking on the cover
with the TOP marking on the contact block, and press the cover toward
the contact block.
TOP marking
Press in
TOP marking
Notes:
1. Once installed, the XW9Z-VL2MF cannot be removed.
2. The XW9Z-VL2MF cannot be installed after wiring.
3. With the XW9Z-VL2MF installed, crimping terminals cannot be used. Use solid
wires.
4. Make sure that the XW9Z-VL2MF is securely installed. IP20 cannot be
achieved when installed loosely, and electric shocks may occur.
Only solid wires can
be used
for IP20 units.