Datasheet

YW Series Emergency Stop Switches
ø22
Emergency Stop Switches Specifications
Standards
Applicable Standards Mark File No. or Organization
UL508
CSA C22.2 No.14
UL/c-UL Listed
File No.E68961
EN60947-5-5
TÜV SÜD
EU Low Voltage Directive
GB14048.5 CCC No. 2006010305196875
R0.8 max.
0
+0.4
+0.4
0
+0.2
0
ø22.3
3.2
24.1
50 minimum
50 minimum
The 3.2-mm-wide key recess
is necessary when the
anti-rotation ring is used.
Mounting Hole Layout
LED Lamp Ratings
Part No. Rated Voltage Rated Current
LSED-6R
6V AC/DC 10 mA
LSED-1R
12V AC/DC 14 mA
LSED-2R
24V AC/DC 14 mA
LSED-HR
110/120V AC/DC 5.5 mA
LSED-M3R
230/240V AC/DC 2.7 mA
Incandescent Lamp Ratings
Part No. Rated Voltage Ratings
LS-T6
6V AC/DC 6.3V 1W
LS-T8
12V AC/DC 18V 1W
LS-T3
24V AC/DC 30V 1W
Contact Ratings (Contact Block)
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Operating Voltage 24V 120V 240V 380V
AC
50/60
Hz
Resistive Load (AC-12) 10A 10A 6A 2A
Inductive Load (AC-15) 10A 6A 3A 1.9A
DC
Resistive Load (DC-12) 8A 2.2A 1.1A
Inductive Load (DC-13) 4A 1.1A 0.55A
Specifications
Operating temperature –20 to +55°C (no freezing)
Operating humidity 45 to 85% RH (no condensation)
Storage temperature –45 to +80°C (no freezing)
Storage humidity 95% RH maximum
Degree of Protection
From panel front: IP65 (IEC 60529)
Terminal: IP20 (IEC 60529)
Insulation Resistance 100 MΩ
Dielectric Strength
Contact block: 2,500V, 1 minute
Pilot light: 2,000V, 1 minute
Vibration Resistance
Operating extremes / Damage limits:
10 to 500 Hz, amplitude 0.35 mm,
acceleration 50 m/s
2
Shock Resistance
Operating extremes: 150 m/s
2
(15G)
Damage limits: 1,000 m/s
2
(100G)
Mechanical Life
(minimum operations)
250,000 (single contact block)
Electrical Life
(minimum operations)
100,000 (single contact block)
www.apem-idec.eu