Datasheet

www.apem-idec.eu
D-051
ø30 XN Series Emergency Stop Switches
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Emergency Stop Switches
X6
XA
XW
XN
SEMI
Standards and Specications
Direct Opening Action
Padlockable, ush bezel, ø60mm jumbo mushroom,
illuminated, LED push-on are available.
IDEC’s original “Safe break action” and reverse energy structure
ensure the highest level of safety.
Safety lock mechanism (IEC 60947-5-5, 6.2)
Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-
1, Annex K)
Short depth behind the panel – only 47.7 mm for 4-contact, illumi-
nated (ush bezel: 60.4 mm, padlockable: 61.4 mm)
Padlockable can be locked using padlocks when latched (main contact:
OFF). The rugged aluminum diecast shroud allows for installing a maxi-
mum of 20 padlocks using a hasp (total weight: 1500g maximum).
Silver with gold contacts.
Red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors are
available.
Contact Ratings
NC main contacts/NO monitor contacts
Rated Insulation Voltage (Ui) 250V
Rated Thermal Current (Ith) 5A
Rated Operating Voltage (Ue) 30V 125V 250V
Rated Operating Current
Main
Contacts
AC
50/60 Hz
Resistive Load
(AC-12)
5A 3A
Inductive Load
(AC-15)
3A 1.5A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
Monitor
Contacts
AC
50/60 Hz
Resistive Load
(AC-12)
1.2A 0.6A
Inductive Load
(AC-14)
0.6A 0.3A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
Contact Material Gold-plated Silver
• Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(May vary depending on the operating conditions and load types.)
• The rated operating currents are measured at resistive/inductive load types
specied in IEC 60947-5-1.
Illumination Ratings (LED)
Rated Voltage Operating Voltage Rated Current
24V AC/DC 24V AC/DC ±10% 15 mA
Note: An LED lamp is built into the contact block and cannot be replaced.
Specifications
Applicable Standards
IEC60947-5-1, EN60947-5-1
IEC60947-5-5, EN60947-5-5
JIS C8201-5-1, UL508, UL991, NFPA79
CSA C22.2 No. 14, GB14048.5
Operating Temperature
Non-illuminated: –25 to +60°C (no freezing)
Illuminated: –25 to +55°C (no freezing)
Storage Temperature –45 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Minimum Force Required for
Direct Opening Action
80N
Minimum Operator Stroke
Required for Direct
Opening Action
4.0 mm
Maximum Operator Stroke
4.5 mm
Contact Resistance
50 mΩ maximum (initial value)
Insulation Resistance
100 MΩ minimum (500V DC megger)
Overvoltage Category II
Impulse Withstand Voltage
2.5 kV
Pollution Degree 3
Operating Frequency 900 operations/hour
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes:
10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s
2
Damage limits:
10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s
2
Durability
(at 900 operations/h,
on-duration 40%)
Mechanical: 250,000 operations minimum
Electrical: 100,000 operations minimum
250,000 operations minimum
(24V AC/DC, 100 mA)
Degree of Protection
Operator: IP65 (IEC60529)
Terminal: IP20 (when XW9Z-VL2MF is installed)
Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2)
Conditional Short-circuit
Current
1000A
Terminal Style M3 screw terminal
Recommended Tighten ing
Torque for Terminal Screw
0.6 to 1.0 N·m
Recommended Tighten ing
Torque for Locking Ring
2.5 N·m
Applicable Wire Size 0.75 to 1.25 mm
2
(AWG18 to 16)
Total Weight of a Hasp and
Padlocks
1500g maximum (padlockable)
Reinforced Insulation
(IEC 60664-1)
Between live part and metal bezel
(ush bezel, padlockable)
Weight
83g (XN1E-LV404Q4MR)
93g (XN1E-BV504MR)
89g (XN5E-LV404Q4MR)
120g (XN4E-LL404Q4MR)
ø30 mm, 4-contact Emergency Stop Switch.
Padlockable and flush bezel are available.