Datasheet

www.apem-idec.eu
D-009
ø16 X6 Series Emergency Stop Switches (Unibody)
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Emergency Stop Switches
X6
XA
XW
XN
SEMI
Third-generation emergency stop switch with Reverse Energy Structure
Smallest in its class
Two button sizes—ø30mm and ø40mm
Two ways of resetting —pulling and turning.
Safety lock mechanism (IEC 60947-5-5; 6.2)
Direct opening action (IEC 60947-5-5; 5.2, IEC 60947-5-1, Annex K)
Degree of protection: IP65 (IEC60529)
Standards and Specications
Specifications
Applicable Standards
IEC 60947-5-1, EN 60947-5-1
IEC 60947-5-5 (Note), EN 60947-5-5 (Note)
JIS C8201-5-1, JIS C8201-5-5, UL508
CSA C22.2 No.14, GB14048.5
Operating Temperature –25 to +60°C (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Storage Temperature –45 to +80°C (no freezing)
Operating Force
Push to lock: 10.5N
Pull to reset: 8.8N
Turn to reset: 0.17 N·m
Minimum Force
Required for Direct Opening
Action
40N
Minimum Operator Stroke
Required for Direct Opening
Action
4.5 mm
Maximum Operator Stroke 4.5 mm
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Overvoltage Category II
Impulse Withstand Voltage 2.5 kV
Pollution Degree 3
Operation Frequency 900 operations/hour
Shock Resistance
Operation extremes: 150 m/s
2
Damage limits: 1000 m/s
2
Vibration Resistance
Operation extremes: 10 to 500 Hz
amplitude 0.35 mm, acceleration 50 m/s
2
Damage limits: 10 to 500 Hz,
amplitude 0.35 mm, acceleration 50 m/s
2
Mechanical Life 100,000 operations minimum
Electrical Life 100,000 operations minimum
Degree of Protection IP65 (IEC 60529)
Short-circuit Protection
250V/10A fuse
(Type aM IEC 60269-1/IEC 60269-2)
Conditional Short-circuit
Current
1000A
Terminal Style Solder terminal, Solder/tab terminal #110
Recommended Tightening
Torque for Locking Ring
0.88 N·m
Applicable Wire Size 1.25 mm
2
maximum (AWG16 maximum)
Terminal Soldering Condition 310 to 350°C, within 3 seconds
Weight (approx.)
ø30mm button: 13g
ø40mm button: 16g
Contact Ratings
Rated Insulation Voltage (Ui) 250V
Rated Thermal Current (Ith) 5A
Rated Operating Voltage (Ue) 30V 125V 250V
Rated Operating Current
(Note)
Main Contacts
AC
50/60 Hz
Resistive Load
(AC-12)
5A 3A
Inductive Load
(AC-15)
1.5A 0.75A
DC
Resistive Load
(DC-12)
2A 0.4A 0.2A
Inductive Load
(DC-13)
1A 0.22A 0.1A
• Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(May vary depending on the operating conditions and load)
• Operational current represents the classication by making and breaking currents
(IEC 60947-5-1).
Note:
TÜV/CCC rating: AC-15 0.75A/250V, DC-13 1A/30V
UL rating: Standard Duty AC 0.75A/250V
Standard Duty DC 1A/30V