Instruction Manual
22
*3. The backlight life refers to the time until the surface brightness reduces to a half after using
continuously at room temperatures.
*4. In high temperature environments battery life may be affected, so retention time may be
reduced.
Recommended continuous turn on time is 15 hours when first use or did not turn on for a long
time. When battery charging and discharging is repeated without that, battery life becomes
shorter than the specification value.
*5. The degree of protection for the operating section after the panel is attached. The compliance
test has been passed, but this is not a guarantee of operation in all environments.
● EMC Specifications
Weight (approx.)
FT1A-*12RA: 300 g
FT1A-*14KA/SA: 250 g
Type Number FT1A-*12RA FT1A-*14KA/SA
Radiated Emission
Class A : 10m
40dBµV/m quasi-peak (30M to 230MHz)
47dBµV/m quasi-peak (230M to 1GHz)
Electrostatic Discharge
Contact : ±6kV
Air : ±8kV
Electromagnetic Field
10V/m (80 to 1000 MHz)
3V/m (1.4 to 2.0 GHz)
1V/m (2 0 to 2.7 GHz)
80% AM (1kHz)
Fast Transient Burst
±2kV (Power, Output terminal)
±1kV (Port, Ethernet, Input
terminal)
±2kV (Power)
±1kV (Port, Ethernet, Input
terminal, Output terminal)
Surge Immunity
±500V (between +24V-0V)
±1kV (between +24V-FE, 0V-FE)
Conducted Radio
Frequency Immunity
10V (Power, Port, Ethernet, Input terminal, Output terminal)
(150kHz to 80MHz)
80% AM (1kHz)