HE1G-L Grip Style Three-position Enabling Switches
Specifications
Applicable Standards
IEC60947-5-1, EN60947-5-1 (TÜV approval)
JIS C8201-5-1, IEC60947-5-8, EN60947-5-8
(TÜV approval)
GS-ET-22 (TÜV approval)
UL508 (UL listed) (screw terminal only)
CSA C22.2 No. 14 (c-UL listed)
(screw terminal only)
KS C IEC60947-5-1/S1-G-1 (KOSHA approval)
Applicable
Standards for Use
ISO12100-1, -2/EN12100-1, -2
IEC60204-1/EN60204-1,
ISO11161/prEN11161
ISO10218/EN775, ANSI/RIA R15.06
ANSI B11.19
Operating Temperature
Silicon rubber boot:
–25 to 60°C (no freezing)
NBR/PVC Polyblend rubber boot:
–10 to 60°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Contact Resistance 100 mΩ maximum (initial value)
Insulation Resistance
Between live and dead metal parts:
100 MΩminimum (500V DC megger)
Between terminals of different pole:
100 MΩminimum (500V DC megger)
Impulse Withstand
Voltage
Screw terminal:
2.5 kV (momentary pushbuttons: 1.5 kV)
Internal connector: 1.5 kV
Electric Shock Protection
Class
Class II (IEC 61140)
Operating Frequency 1,200 operations per hour
Mechanical Durability
Position 1 → 2 → 1:
1,000,000 operations minimum
Position 1 → 2 → 3 → 1:
100,000 operations minimum
Electrical Durability
100,000 operations minimum (rated load)
1,000,000 operations minimum (24V AC/DC, 100 mA)
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 1,000 m/s
2
Vibration Resistance
Operating extremes:
5 to 55 Hz, amplitude 0.5 mm minimum
Damage limits:
16.7 Hz, amplitude 1.5 mm minimum
Applicable Wire
Screw terminal:
0.14 to 1.5 mm
2
(AWG16 to 25)
Internal connector:
0.05 to 0.86 mm
2
(AWG18 to 30)
Applicable Cable Outside diameter ø7 to 13 mm
Conduit Port Size
M20 (cable gland is supplied with the grip style
enabling switch)
Terminal Tensile
Strength
20N minimum
Terminal Screw
Tightening Torque
0.5 to 0.6 N·m
Degree of Protection
HE1G-L21SM: IP66 (IEC 60529)
HE1G-L20ME: IP65 (IEC 60529)
HE1G-L20MB: IP65 (IEC 60529)
HE1G-L21SMB: IP65 (IEC 60529)
Conditional Short-circuit
Current
50A (250V) (Use 250V/10A fast-blow fuse for short
circuit protection.)
Direct Opening Force 70N minimum (monitor switch)
Operator Strength
500N minimum (when pressing the entire button
surface)
Weight (approx.)
HE1G-L21SMC: 190g
HE1G-L21SM/L21SMCB/L20MCB: 200g
HE1G-L21SMB/L20MB: 210g
HE1G-L20MCE: 230g
HE1G-L20ME: 240g
Operating Characteristics
HE1G-L21SM, HE1G-L21SMC,
HE1G-L21SM-1N, HE1G-L21SMC-1N
• Terminals 1-2/A1-B1 and 3-4/A2-B2 are outputs of the 3-position enabling
switch.
• Terminals 5-6/A3-B3 are outputs of the monitor switch.
• The above operation characteristics show when the center of the grip style
enabling switch button is pressed. Because two contacts are designed to
operate independently, pressing the edge of the button turns on one contact
earlier than the other contact, causing a delay in operation. To avoid this,
always press the center of the button.
Dimensions
HE1G-L21SM, HE1G-L21SMC,
HE1G-L21SM-1N, HE1G-L21SMC-1N
Internal Connector Terminal No.
Connector
Tyco Electronics D-1200D series
• Receptacle housing: 1-1827864-4
• Receptacle contact
1827586-2: AWG28 to 30
(Hand tool: 1762952-1)
1827587-2: AWG22 to 28
(Hand tool: 1762846-1)
1827588-2: AWG22 to 28
(Hand tool: 1762950-1)
1827589-2: AWG18 to 22
(Hand tool: 1762625-1)
Accessory
Mounting Bracket HE9Z-GH1 (for hanging the switch)
50
20
33
81
Material: SUS304
SUS304
Thickness: 3.0 mm
t=3.0mm
(For M5 mounting screws)
2-øM.5
86
Plastic Coating
Note: Available for HE1G/HE1G-L/HE9Z-GSH51 only.