Datasheet

www.apem-idec.eu
D-075
HE5B ø16mm Round Three-position Enabling Switches
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Enabling Switches
HE1B
HE2B
HE3B
HE5B
HE6B
HE2G
HE1G-L
Actuator w/
Plastic Holder
Round-shaped operator for ø16 mm mounting hole.
3-position enabling switch with two contacts, ideal for installing in small teaching pendants.
• See website for details on approvals and standards.
HE5B
Shape Style
Contact
Conguration
Part No. Ordering No.
Package
Quantity
With Rubber Boot
Silicon
Rubber
Y: yellow
B: black
2 contacts
(3-position
switch)
HE5B-M2P
HE5B-M2P
1
HE5B-M2PPN10
10
NBR/PVC
HE5B-M2PN1
HE5B-M2PN1 1
HE5B-M2PN1PN10 10
• Specify a rubber boot color code in place of in the Ordering No.
Contact Ratings
Rated Insulation Voltage (Ui)
125V
Rated Thermal Current (Ith)
3A
Rated Voltage (Ue)
30V 125V
Rated Current (Ie)
AC
Resistive Load (AC-12)
0.5A
Inductive Load (AC-15)
0.3A
DC
Resistive Load (DC-12)
1A
Inductive Load (DC-13)
0.7A
Contact Conguration (3-position switch)
2 contacts
Minimum applicable load (reference): 3V AC/DC, 1mA
(Applicable operation area depends on the operating conditions and load.)
Specifications
Applicable Standards
IEC/EN60947-5-8 (TÜV approval), IEC/EN60947-5-1
UL508 (UL recognized), CSA C22.2 No. 14 (c-UL recognized),
GB14048.5 (CCC approval)
Applicable Standards
for Use
ISO12100-1, -2/EN12100-1, -2, IEC60204-1/EN60204-1
ISO11161/prEN11161, ISO10218/EN775, ANSI/RIA
R15.06, ANSI B11.19
Operating
Temperature
Silicon rubber boot: –25 to 60°C (no freezing)
NBR/PVC Polyblend rubber boot: –10 to 60°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree
2 (inside panel, terminal side)
3 (outside panel, operator side)
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance
Between live and dead metal parts: 100 MΩminimum
(500V DC megger)
Between terminals of different pole: 100 MΩminimum
(500V DC megger)
Impulse Withstand
Voltage
1.5 kV
Operating Frequency 1,200 operations per hour
Mechanical Durability
Position 1 2 1: 1,000,000 operations minimum
Position 1 2 3 1: 100,000 operations minimum
Electrical Durability 100,000 operations minimum
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 500 m/s
2
Vibration Resistance
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Damage limits: 5 to 55 Hz, amplitude 1.5 mm
Terminal Style Solder terminal
Applicable Wire 0.5 mm
2
maximum per line
Terminal Soldering
Heat Resistance
310 to 350°C, 3 seconds maximum
Terminal Tensile
Strength
20 N minimum
Locking Ring
Recommended
Tightening Torque
0.29 to 0.49 N·m
Degree of Protection IP65 (IEC 60529)
Conditional Short-
circuit Current
50A (125V) (Use 250V/10A fast-blow fuse
for short circuit protection.)
Operator Strength
250N minimum (when pressing the entire operator surface)
Weight (approx.) 8g (without rubber boot), 9g (with rubber boot)