Datasheet
www.apem-idec.eu
D-088
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Enabling Switches
HE1B
HE2B
HE3B
HE5B
HE6B
HE2G
HE1G-L
Actuator w/
Plastic Holder
HE2G Grip Style Three-position Enabling Switches
Solder Terminal
Wire Length inside the Switch
Grip Style Enabling Switch
Momentary
Pushbutton/
Key Selector
Switch
Emergency
Stop Switch
Pilot
Light
NO1
C1 11 12 31 32
NO2
C2
C
NO NC
1 2 + –
Wire
stripping
length
L1 (mm)
40 45 50 60 50 60 85 80 120 110 115
Wire
stripping
length
L2 (mm)
L2=5mm
Emergency
Stop Switch
Momentary Pushbutton/
Key Selector Switch
Grip Style
Enabling Switch
Pilot Light
L1
L2
<Example>
Sheath
Emergency
Stop Switch
Grip Style
Enabling Switch
Applicable Wire Size
0.5mm
2
maximum (Observe the requirements of IEC 60204-1 for wiring.)
Recommended Tightening Torque
Parts for tightening Torque
A
Base and rubber kit (M4 screw × 4)
1.1 to 1.3 N·m
B Cable gland and grip style enabling switch 2.7 to 3.3 N·m
C Cable gland 2.7 to 3.3 N·m
D HE2B Enabling Switch (M3 screws × 2) * 0.5 to 0.8 N·m
Note: The recommended tightening torques of B and C are for the supplied cable
gland. When using another cable gland, refer to the tightening torque of
the cable gland used.
* For replacing HE2B enabling switch or rubber boot only
mended connector is used. When using another connec tor, refer to the speci-
cations of the connector used.
Rubber Boot Kit
Cable Gland
Base
Base
B
C
D (M3 scew × 2)
A (M4 scew × 4)
Rubber Boot Kit
Connector Terminal
Wire Length inside the Switch
Grip Style
Enabling
Switch
Momentary
Pushbutton/Key
Selector Switch
Emergency
Stop Switch
Wire stripping length L1 (mm) 20 60 75
Cable gland for
emergency stop switch
Cable gland for
momentary pushbutton
/
key selecetor switch
Cable gland for
grip style enabling switch
L1
Sheath
<Example
>
Applicable cable gland
on cable side
Applicable wire size for the cable gland on cable side
• 0.05 to 0.86mm
2
(AWG18 to 30): Check the compliance with receptacle and
contact.
Tool: 1762846-1 (manual tool)
Note: When using stranded sires, make sure that loose wires do not cause short
circuit. Also, do not older the terminals to prevent loose wires. Use copper
wire of 60°C or 75°C temperature rating in order to comply with UL508.
Observe the requirements of GS-ET-22: 2003, 4.2.6 for wiring.
Instructions