Instruction Manual

126
HS1C-P Interlock Plug Unit with Door Lock
Instructions
Minimum Radius of Hinged Door
•When using the interlock plug unit for a hinged door, refer to the
minimum radius of doors shown below. For the doors with small
minimum radius, use angle adjustable actuators (HS9Z-A3).
Note: Because deviation or dislocation of hinged door may occur
in actual applications, make sure of the correct operation
before installation.
HS9Z-A2 Actuator
• When the door hinge is on the extension line of the interlock plug unit
surface:
230 mm
Minimum Radius
130 mm
Minimum Radius
Door Hinge
• When the door hinge is on the extension line of the actuator mounting
surface:
HS9Z-A2 Actuator
Door Hinge
240 mm
Minimum Radius
400 mm
Minimum Radius
HS9Z-A3 Actuator
• When the door hinge is on the extension line of the interlock plug unit
surface:
50 mm
Minimum Radius
• When the door hinge is on the extension line of the actuator mounting
surface:
80 mm
Minimum Radius
HS9Z-A3 Actuator
Actuator Angle Adjustment
•Using the angle adjustment screw, the actuator angle can be
adjusted (refer to the dimensional drawing). Adjustable angle: 0
to 20°
•The larger the adjusted angle of the actuator, the smaller the ap-
plicable radius of the door opening.
•After installing the actuator, open the door. Then adjust the actua-
tor so that its edge can be inserted properly into the actuator
entry slot of the interlock switch.
•Recommended tightening torque of angle adjustment screw:
0.8 N·m
•After adjusting the actuator angle, apply Loctite to the adjustment
screw so that the screw will not loosen.
Applicable Crimping Terminal
ø3.6 min.
3.5 max.
3.6 min.
6.9 max.
ø4.1 min.
3.8 max.
3.5 min.
7.6 max.
Terminal Nos. 7, 8 Ground Terminal: E
•Use an insulation tube on the crimping terminal
Insulation
Tube
Wire
Applicable
Crimping
Terminal
Approx.
4 mm
Terminal No. 1 to 6
•Direct wiring using either solid or stranded wires.
•When using stranded wires, make sure that loose wires do not
cause short circuit. Also, do not solder the terminal to prevent
loose wires.
When using Ferrules
Ferrules (Phoenix Contact)
Part No. Applicable Wire
AI 0.75-8 GY 0.5 to 0.75 mm
2
AI 1.0-8 RD 0.75 to 1.0 mm
2
AI 1.5-8 BK 1.0 to 1.5 mm
2
Crimping Tool: CRIMPFOX UD6
Applicable Wire Size
•Terminal Nos. 1, 2, 5, 6, 7, 8: 0.5 to 0.75 mm
2
•Terminal Nos. 3, 4, E: 1.0 to 1.25 mm
2
Installing the Interlock Plug Unit
Mount the interlock plug unit on a fixed machine or guard,
and mount the actuator on the hinged door. Do not mount
both safety plug unit and actuator on the hinged doors,
otherwise malfunction will occur.
Door Stop
HS1C-P
Interlock Plug Unit
Latch
Aplication on Sliding Doors
Door
HS9Z-A1
Actuator
Application on Hinged Doors
Door
HS1C-P
Interlock Plug Unit
HS9Z-A2 Actuator
Latch
Actuator
HS9Z-A1