Datasheet

84
HS1L Interlock Switches with Solenoid
Ratings
Contact Ratings
Rated Insulation Voltage (Ui)
300V
Rated Operating Current (Ith)
10A
Rated Operating Voltage (Ue)
30V 125V 250V
Rated
Operating
Current
(Ie)
AC
Resistive Load (AC-12)
10A 10A 6A
Inductive Load (AC-15)
10A 5A 3A
DC
Resistive Load (DC-12)
8A 2.2A 1.1A
Inductive Load (DC-13)
4A 1.1A 0.6A
• Minimum applicable load (reference value): 3V AC/DC, 5mA
(Applicable range may vary with operating conditions and load types.)
• TÜV rating: AC-15 3A/250V, DC-13 4A/30V
UL, c-UL rating: A300
Pilot duty: AC 3A/250V
Pilot duty: DC 4A/30V
• CCC rating: AC 15 3A/250V, DC-13 4A/30V
Solenoid Unit and LED Indicator
Lock Mechanism
Spring Lock Solenoid Lock
Solenoid
Rated Operating
Voltage
24V DC (100% duty cycle)
Rated Current 200 mA (initial value)
Coil Resistance 120Ω (at 20°C)
Pickup Voltage Rated voltage × 85% max. (at 20°C)
Dropout Voltage Rated voltage × 10% max. (at 20°C)
Maximum Continuous
Applicable Voltage
Rated voltage × 110%
Maximum Continuous
Applicable Time
Continuous
Insulation Class Class F
LED
Rated Operating
Voltage
24V DC
Rated Current 10 mA
Light Source LED
Illumination Color Green (G), Red (R)
Specifications
Applicable Standard
ISO14119
IEC60947-5-1
EN60947-5-1 (TÜV approved)
GS-ET-19 (TÜV approved)
UL508 (UL listed)
CSA C22.2 No. 14 (c-UL listed)
GB14048.5 (CCC approved)
IEC60204-1/EN60204-1
(applicable standards for use)
Operating Temperature −20 to +55°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Overvoltage Category III
Impulse Withstand
Voltage
4.0 kV
(between LED, solenoid and ground: 1.5 kV)
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance
Between live and dead metal parts:
100 MΩ minimum (500V DC megger)
Between terminals of different poles:
100 MΩ minimum (500V DC megger)
Electric Shock
Protection
Class II (IEC 61140)
Degree of Protection IP67 (IEC 60529)
Shock Resistance Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes:
10 to 55 Hz, amplitude 0.35 mm
Damage limits: 30 Hz, amplitude 1.5 mm
Actuator Operating
Speed
0.05 to 1.0 m/s
Direct Opening Travel 11 mm minimum
Direct Opening Force 50N minimum
Actuator Retention
Force when Locked
3000N minimum (GS-ET-19)
See page 87 for dimensions.
Operating Frequency 900 operations per hour
Mechanical Durability 1,000,000 operations minimum (GS-ET-19)
Electrical Durability
100,000 operations minimum
(AC-15 3A/250V)
1,000,000 operations minimum
(24V AC/DC, 100mA)
(operating frequency 900 operations per hour)
Conditional Short-circuit
Current
100A (250V) (Use 250V/10A fast acting type
fuse for short-circuit protection.)
Weight (approx.) 450g (HS1L-DQ44)
3000N locking strength (largest in class)! *
Suitable for large and heavy doors.
•Same actuator as HS1E (actuator retention force 3000N)
•Six contacts in a compact housing (same size as HS1E)
•Same dimensions and mounting hole layouts as HS1E
(Size: 35 × 104 × 129 mm)
•Door open, closed, and locked statuses can be monitored
for various applications.
•Energy efficient new solenoid unit. 32% less solenoid
current consumption compared with HS1E.
•Manual unlock key and LED indicator are standard.
•Manual unlock key allows for manual unlocking in the event
of power failure or maintenance.
•Indicator has an independent circuit, and can be used for
various purposes.
•Two locking mechanisms to choose from—spring lock
(unlocked with energized solenoid) or solenoid lock (locked
with energized solenoid).
•M3 terminal screws for wiring.
•Wide operating temperature range (–20 to +55°C).
(Zinc Diecast)
Manual
Unlock Key
L-shaped Actuator
(3000N) (SUS304)
Angle Adjustable (vertical)
Actuator (3000N) (SUS304)
Straight Actuator
(3000N) (SUS304)
LED
Indicator
* As of December 2011, according to IDEC research of
plastic interlock switches with solenoid.

Summary of content (8 pages)