HS5 Series Slide Handle Actuator
•In order to avoid electric shock or re, turn power off before
installation, removal, wire connection, maintenance, or inspection of
the interlock switch.
•Do not disassemble or modify the interlock switch, otherwise a
breakdown or an accident may occur.
•The slide handle actuator can be used with the HS5D, HS5E-L, and
HS5E-KL/HS5L-L only. Do not use with other interlock switches.
•When using the slide handle actuator in the safety-related part of the
system, make sure of proper operation while observing the safety
standards and regulations of the relevant country or region where
the actual machine/system is used. Also, perform a risk assessment
before operation.
•Read the instruction sheet of interlock switch before installing the
slide handle actuator.
•Install a mechanical door stop at the end of the door to protect the
interlock switch against excessive force.
•Do not force the handle when the door is locked. Otherwise damage
will result.
•Install the slide handle actuator on the
outside of the door. Do not install inside
the door, otherwise the door cannot be
opened or closed by the operator, affecting
the operation and causing danger to the
operator.
•Do not close the door when the bolt is slid
out, otherwise damage will result.
•Install the slide handle actuator as shown
at right, so that the cable hub faces downward. Do not install in any
other direction.
Handle Operation
•Lift the knob completely
before operating the
handle, as shown at right.
Make sure to lift the knob
rst, otherwise damage
may be caused.
•Do not attempt to close the door without lifting the knob, otherwise
damage will result.
•The knob is latched when the handle unit is open, preventing the
unintended closing of the door. Lifting the knob unlatches the knob.
•Be careful so that your hand or nger is not caught when operating
the handle actuator.
Padlockable Bolt
•Install the padlock or hasp on
the padlockable bolt as shown
at right.
•Make sure that the load on
the padlockable bolt does not
exceed 50N, otherwise the slide handle actuator may be deformed or
damaged.
•The applicable shackle diameter is ø6 to 13.
Applicable shackle diameter:
ø6 to 13mm
Bolt
Cable
Knob
Hole for Padlock
or Hasp
25
35
14
Padlockable Bolt
•The actuator cannot be inserted
using the rear lever.
Mounting
•Conrm that the package contains
the following parts.
Unit Parts Quantity
HS9Z-EH5L
Switch Base Unit 1
Handle Unit 1
Actuator 1
Plastic Stopper 1
One-side Screw (M5) 2
Spring Washer 2
Rear Lever 1
Interlock Switch Head Direction
•Before installing the interlock switch, change the head direction
according to the door orientation (right-hand or left-hand) as shown
below. The head direction can be changed by removing the four
screws from the corners of the interlock switch head and rotating
the head. Make sure to turn the manual unlock to UNLOCK when
changing the head direction after wiring. Also, make sure that no
foreign object enters into the interlock switch. Tighten the screws
tightly, without leaving space between the head and body, otherwise
the interlock switch may malfunction. Recommended tightening
torque: 0.9 to 1.1 N·m.
For left-hand
doo
r
For
right-hand door
Handle Unit
Handle Unit
Interlock
Switch
Interlock
Switch
Screws
Installing the Switch Base Unit
When using HS5E-L/HS5E-KL/HS5L-L
1. Using M4 mounting screws, fasten the interlock switches on the
switch base unit. Mounting screws are not supplied and must be
provided by the user.
Mounting screw thread length: 36 to 40mm
Switch Base Unit
Mounting Screws (M4)
HS5E Interlock Switch
2. Fasten the switch base unit on the mounting frame or panel.
Mounting screws and nuts are not supplied and must be provided by
the user.
Rear Lever
Operating Instructions
Download catalogs and CAD from http://eu.idec.com/downloads