Datasheet

16
HS6B Subminiature Interlock Switches
World-class compactness with three poles of contacts.
Vertical/horizontal Angle
Adjustable Actuator (for
hinged door)
Right-angle Actuator
(SUS304)
Straight Actuator
(SUS304)
World’s smallest switch: 30 × 30 × 78 mm
Dual contacts and monitor contacts achieve the highest safety
category (ISO 13849-1, EN 954-1)
Two actuator entry slots provide flexibility for installation options.
Integral cable design minimizes wiring, preventing wiring
mistakes.
Can be mounted in two directions.
Degree of protection (contacts): IP67 (IEC 60529)
Housing allows drainage.
NC contacts are direct opening action (IEC/EN 60947-5-1).
Proprietary actuators prevent unauthorized opening of the
contacts (ISO14119, EN1088).
Double
Insulation
Direct
Opening
Action
Types
Actuators
Note: Select an actuator that moves in the direction required by the
hinged door and interlock switch (see pages 17 and 18).
Contact Ratings
Minimum applicable load (reference): 3V AC/DC, 5mA
Ratings approved by safety agencies
C300: AC-15, 0.75A/240V
Q300: DC-13, 0.27A/250V
Specifications
Contact Configuration Cable Length
Type No.
(Package quantity: 1)
1NC-1NO
1m HS6B-11B01
3m HS6B-11B03
5m HS6B-11B05
2NC
1m HS6B-02B01
3m HS6B-02B03
5m HS6B-02B05
2NC-1NO
1m HS6B-12B01
3m HS6B-12B03
5m HS6B-12B05
3NC
1m HS6B-03B01
3m HS6B-03B03
5m HS6B-03B05
Description
Type No.
(Package quantity: 1)
Straight HS9Z-A61
Right-angle HS9Z-A62
Horizontal/vertical Angle Adjustable
(for hinged doors) (Note)
HS9Z-A65
HS9Z-A66
Rated Insulation Voltage (Ui) 300V
Rated Current (Ith) 2.5A
Rated Voltage (Ue) 30V 125V 250V
Rated
Current
(Ie)
AC
Resistive load (AC-12) 2.5A 1.5A
Inductive Load (AC-15) 1.5A 0.75A
DC
Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive Load (DC-13)2.3A 0.55A 0.27A
3433
12
Zb
11
3231
11
Zb
12
3231
12
22
Zb
11
21
31
21
11
Zb
32
22
12
Applicable Standards
UL508 (UL listed)
CSA C22.2, No. 14 (c-UL listed)
ISO 14119
EN 1088
IEC 60947-5-1
EN 60947-5-1 (DEMKO approval)
GS-ET-15 (BG approval)
IEC 60204-1/ EN 60204-1
(applicable standards for use)
Applicable Directive 73/23/EEC (Low Voltage Directive)
Operating
Temperature
–25 to +70°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Impulse Withstand
Voltage
4 kV
Insulation Resistance
(500V DC megger)
Between live and dead metal parts:
100 MΩ minimum
Between terminals of different poles:
100 MΩ minimum
Contact Resistance
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Electric Shock
Protection Class
Class II (IEC 61140)
Degree of Protection IP67 (IEC 60529)
Shock Resistance
Operating extremes: 300 m/s
2
(30G)
Damage limits: 1000 m/s
2
(100G)
Vibration Resistance
Operating extremes:
5 to 55 Hz, amplitude 0.5 mm
Damage limits:
30 Hz, amplitude 1.5 mm
Actuator Operating
Speed
0.05 to 1.0 m/s
Direct Opening Travel 8 mm minimum
Direct Opening Force 60N minimum
Operating Frequency 1200 operations/h
Mechanical Durability 1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations minimum
(operating frequency 1200 operations/h,
load AC-12 250V/1.5A, DC-12 250V/0.2A)
Conditional
Short-circuit Current
50A (250V) (Use 250V/10A fast-blow fuse for short-
circuit protection.)
Housing Color Black
Cable UL2464 No. 20 AWG (6-core)
Weight (approx.) 120g (HS6B-03B01)
(07/03/16)