Interlock Switches with Solenoid HS5L 2-Contact/4-Contact SAFE T Y SWITCH Protecting workers on-site
S Interlock Switch a f 2-Contact e New 2-contact interlock Designed with the requi eliminating excessive fe t y Advantages S w Interlock switches usually have more contacts than needed. i Many interlock switches on the market have 4 or 6 contacts. These interlock switches are used as they are, even though that many contacts are not used. t c h The revised EN ISO 14119 standard requires usage of two interlock devices to achieve PLe when using a Type 2 interlock device.
switches with solenoid. red safety level, while atures. Applications Ideal as a safety measure for use on machines that do not shut down immediately or maintain high temperatures.
S Interlock Switch a f 2-Contact 4-Contact e IDEC ensures reliability 2-contact and 4-contact t y Compact Design S w Size is reduced by 13% from conventional models.∗ Mounts on small doors and aluminum frames of machines. Compact design with 2- and 4-contacts reduce installation space. Greater flexibility in machine design. i t h 145.7 127 c HS5L ∗ Except two-conduit model Conventional Model HS5E r shor te % 3 . x1 Appro ared (Comp with ID EC pro ducts ) All dimensions in mm.
and performance. interlock switches with solenoid. Spring clamp terminals Two-conduit Model Spring clamp terminals offer excellent vibration resistance, preventing wires from loosening. No need for additional tightening. Cable can be connected to the right, left, or bottom (for straight cable orientation) of the terminal cover. Possible to use long marking tubes with the wiring cables. Energy saving! Solenoid energy consumption: 200mA Reduced by 25% from conventional HS5E series.
S Wide variety of actuators for interlock switches enhance flexibility and usability! Actuator a f HS5 series e Actuators can be selected according to door shapes and usage, and can be installed flexibly according to the installation site. t y Wide variety of actuators S Actuators can be selected according to door shapes and usage.
HS5L Interlock Switches with Solenoid (2-Contact) Two-contact solenoid interlock switches ideal for use on applications such as food machines and injection molding machines. ••Spring clamp terminal block prevents loosening of wires due to vibration. ••Gold-plated contacts suitable for small loads. ••Spring lock models (unlocks when the solenoid is energized) and solenoid lock models (locks when solenoid is energized) are available.
HS5L Interlock Switches with Solenoid (2-Contact) HS5L Interlock Switches with Solenoid (2-Contact) 2-Contact Package Quantity: 1 Circuit Code Contact Configuration Spring lock Gland Port Size Solenoid Part No.
HS5L Interlock Switches with Solenoid (2-Contact) Circuit Diagrams and Operating Characteristics Solenoid Lock Status 1 Door Closed Machine ready to operate Solenoid energized Interlock Switch Status Status 2 Status 3 Door Closed Machine cannot be operated Solenoid de-energized Door open Machine cannot be operated Solenoid de-energized Unlocking using Manual Unlock Key Status 4 Door open Machine cannot be operated Solenoid energized Door Closed Machine cannot be operated Solenoid de-energized ➝ ener
HS5L Interlock Switch with Solenoid (4-Contact) Four-contact solenoid interlock switches ideal for use on limited mounting spaces such as small doors. ••Spring clamp terminal block prevents loosening of wires due to vibration. ••A variety of circuits. Dual safety circuit and four-circuit independent outputs available. ••Gold-plated contacts suitable for small loads. ••Spring lock models (unlocks when the solenoid is energized) and solenoid lock models (locks when solenoid is energized) are available.
HS5L Interlock Switch with Solenoid (4-Contact) HS5L Interlock Switches with Solenoid (4-Contact) 4-Contact (Spring Lock/Solenoid Lock) Circuit Code Package Quantity: 1 Contact Configuration Gland Port Size Spring lock Solenoid Part No.
HS5L Interlock Switch with Solenoid (4-Contact) 4-Contact/Rear Unlocking Button (Spring Lock) Circuit Code Package Quantity: 1 Contact Configuration Gland Port Size Spring lock Part No.
HS5L Interlock Switch with Solenoid (4-Contact) Circuit Diagrams and Operating Characteristics 4-Contact/Rear Unlocking Button (Spring Lock) Status 1 Status 2 Door Closed Machine ready to operate Solenoid de-energized Interlock Switch Status Status 3 Door Closed Machine cannot be operated Solenoid energized When unlocking manually Status 4 Door open Machine cannot be operated Solenoid energized Door open Machine cannot be operated Solenoid de-energized Door Closed Machine cannot be operated Soleno
HS5L Interlock Switch with Solenoid (4-Contact) Circuit Diagrams and Operating Characteristics 4-Contact (Solenoid Lock) Status 1 Status 2 Door Closed Machine ready to operate Solenoid energized Interlock Switch Status Status 3 Door Closed Machine cannot be operated Solenoid de-energized Unlocking using Manual Unlock Key Status 4 Door open Machine cannot be operated Solenoid de-energized Door open Machine cannot be operated Solenoid energized Door Closed Machine cannot be operated Solenoid de-ener
HS5L Interlock Switch with Solenoid (4-Contact) Circuit Diagrams and Operating Characteristics 4-Contact (Solenoid Lock) Status 1 Status 2 Door Closed Machine ready to operate Solenoid energized Interlock Switch Status Status 3 Door Closed Machine cannot be operated Solenoid de-energized Unlocking using Manual Unlock Key Status 4 Door open Machine cannot be operated Solenoid de-energized Door open Machine cannot be operated Solenoid energized Door Closed Machine cannot be operated Solenoid de-ener
HS5L Interlock Switch with Solenoid (4-Contact) Circuit Diagrams and Operating Characteristics 4-Contact/Dual Safety Circuit, 4-Contact/Dual Safety Circuit/Rear Unlocking Button (Spring Lock) Status 1 Status 2 Door Closed Machine ready to operate Solenoid de-energized Interlock Switch Status Status 3 Door Closed Machine cannot be operated Solenoid energized Unlocking using Manual Unlock Key Status 4 Door open Machine cannot be operated Solenoid energized Door open Machine cannot be operated Solenoi
Actuators for HS5 Series Interlock Switches Actuator Description Part No. Straight HS9Z-A51 Straight with rubber bushings HS9Z-A51A Right-angle HS9Z-A52 Right-angle with tubber bushings HS9Z-A52A Angle adjustable (vertical) HS9Z-A53 Angle adjustable (vertical/horizontal) with plate HS9Z-A55S Angle adjustable (vertical/horizontal) HS9Z-A55 Package Quantity Remarks Actuator retention force is Fzh=1400N. 1 Actuator retention force is Fz=500N.
Actuators for HS5 Series Interlock Switches Actuator Dimensions and Mounting Hole Layouts (Horizontal Swing) Angle Adjustment (M3 hexagon socket head bolt) Orienting Insert 19.5 20° 7 18.5 14.4 ) R (M 2.1 1 4 Hole ) 3.6 28.5 (Vertical Swing) Note: Actuator Stop Film (supplied with the actuator) Orienting Insert Note: Actuator Stop Film (supplied with the actuator) 48.4 38 R2. 1 1 (M 3.6 4 Hole 28.
HS5L Interlock Switches with Solenoid Accessory Dimensions and Mounting Hole Layouts All dimensions in mm. 2.5 HS5L Interlock Switch with Actuator 3.3mm line 7 Mounting tolerance range: ±1.0 47 58 31 15 10 to 15 10 to 15 0.8mm line (Mounting tolerance range: 0.8 0.8 6-M5 Screw +2.
Actuators for HS5 Series Interlock Switches HS5L- 4LM- G (with rear unlocking button) All dimensions in mm. When using Horizontal Mounting/Straight Actuator (HS9Z-A51) 3 9 44.5 Rear Unlocking Button 27 86.5 Manual Unlock LED (with Indicator) 18 3.9 7.7 .2 R2 (24) 16.8 15 9 1 4 12.5 36.2 20 127 1 0 6 6.2 42.2 5.2 Accessories (supplied) 11 5 ø3 61.6 30 Slot Plug 6.5 (24.5) Manual Unlocking Key ø14 1 86.5 10 35 9 17.
HS5L Interlock Switches with Solenoid Accessories Description Part No. Package Quantity Panel Thickness * (X) HS5L Interlock Switch Rear Unlocking Button Kit (When mounting HS5L-L directly) 1 33 < X ≤ 43 23 < X ≤ 33 HS9Z-FL53 HS9Z-FL54 Rear Unlocking Button Kit 43 < X ≤ 53 HS9Z-FL55 Dimensions All dimensions in mm. Rear Unlocking Button Kit (HS9Z-FL5) Button (PA66) 16 30 Pin (Stainless Steel) 33 60.9 0 ing te) o 3 ck (No 2 t nlo ø2 ar U Hole Re tton Bu 25.9 25.9 31.
HS5L Interlock Switches with Solenoid Safety Precautions ••In order to avoid electric shock or fire, turn power off before installation, removal, wiring, maintenance, or inspection of the interlock switch. ••If relays are used in the circuit between the interlock switch and the load, use only safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the interlock switch.
HS5L Interlock Switches with Solenoid Instructions When using the interlock switch for a hinged door, refer to the minimum radius of doors shown below. Especially for doors with a small turning radius, use vertical/horizontal movable actuators (HS9Z-A53/A55). Note: Because deviation or dislocation of a hinged door may occur in actual applications, make sure of the correct operation by installing the actual machine first before use.
HS5L Interlock Switches with Solenoid Instructions Installing the Head Spring Loaded Actuator Do not use plastic and metallic heads of HS5D interlock switches on the HS5L. Be sure to use HS5L metallic heads. ∗∗The metal heads of the HS5D and HS5L look similar. When using these interlock switches adjacently, ensure that the heads are not interchanged. ••When using the actuator, be careful of protruding ends. ••Regardless of door types, do not use the HS9Z-BA5 actuator as a door lock or a door stop.
HS5L Interlock Switches with Solenoid Instructions Adjustment Manual Unlocking Adjustment Procedure Spring lock 1. Make a hole at A or C. 2. Fasten temporarily with screws, and check the actuator position. 3. Make a hole at B and fix the actuator using a screw or a rivet. ••3.3mm line The mounting reference position is where the door is fully closed, and there is a 0.8mm space between the safety switch and HS9Z-BA5, but can be adjusted up to the 3.3mm line.
HS5L Interlock Switches with Solenoid Instructions Installing the Rear Unlocking Button Kit 1. Install the connecting rod onto the push rod on the HS5L-L rear unlocking button interlock switch. 2. A pin is attached to the connecting rod. Insert the pin into the hole in the push rod, using pliers. Unlocking the Manual Lock Using the Rear Unlocking Button Use the rear unlocking button when a worker is locked inside a safety fence (hazard area).
HS5L Interlock Switches with Solenoid 8 to 9mm Instructions Applicable Cable Glands ••For wiring, use screwdrivers as shown in the right. (The shape of the tip of the screwdriver is in accordance with DIN5264) ••The inserting port of the wire and screwdriver, and direction of the tip is as shown in the diagram below. Use a cable gland with IP67 protection degree. Applicable Cable Gland Dimensions M20 9mm max. 2.5 0.4 30mm max.
HS5L Interlock Switches with Solenoid Changing the cable orientation (two-conduit model) Connector Wiring Cable orientation can be changed on two-conduit models (HS5L-4SM-G/HS5L-4LSM-G). Straight, left, and right orientation is available. When shipped, the terminal cover is installed on the HS5L for straight or left cable orientation. See below for mounting the cable rightward. ➀ Remove the cover mounting screws (M3×2) and remove the HS5L from the cover. ➁ Rotate the cover 180º.