ø22mm YW Series Control Units (07/12/13)
Innovative Design, Space-Saving, Safety, and Self-Cleaning Contacts Emergency Stop Switches Satisfy International Standards • Safety Lock Mechanism When the emergency stop signal has been generated during actuation of the emergency stop device, the emergency stop function shall be maintained until the emergency stop device is reset (disengaged) (IEC 60947-5-5, 6.2).
Save Safety YW Safety series Reliable Integrated Finger-safe Terminal Cover Degree of Protection: IP20 (From panel front: IP65) Metal bezels are available for pushbuttons, illuminated pushbuttons, selector switches, and key selector switches. Save New Contact Block Design YW series FA CB CB CB FA CB 10 10 10 30 15 15 30 CB: Contact block FA: Full-voltage adapter The new contact block design reduces the depth behind the panel.
YW Series Control Units Space-saving, 10-mm-thick contact blocks. Removable operator. • Compact and light-weight • IP20 finger-safe screw terminals (IEC 60529) • Emergency stop switches feature safety lock mechanism, direct opening action, and safe pushbutton design. • Metal bezel, unibody pilot lights, and key selector switches available. • Separate contact block makes installation and removal easy. Pilot lights feature a large lens for a wide viewing angle.
YW Series Control Units ø22 Emergency Stop Switches Style Operation Contact Mushroom ø40mm Pushlock Pull/Turn Reset Type No. 1NC YW1B-V4E01R 2NC YW1B-V4E02R 3NC YW1B-V4E03R 1NO-1NC YW1B-V4E11R 1NO-2NC YW1B-V4E12R 2NO-1NC YW1B-V4E21R Button Color Code Red only Dimensions Panel Thickness 0.8 to 6 10 10 10 Note: The button is locked when pressed, and is reset when either pulled or turned clockwise. Locking Ring Gasket 41.4 28.6 M3.5 Terminal Screw Contact Block 0 ø4 45.8 32.
ø22 YW Series Control Units Pushbuttons with Plastic Bezel Style Operation Contact Flush 1NO 1NC 2NO 2NC 1NO-1NC 3NO 3NC 2NO-1NC 1NO-2NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC Momentary Maintained Extended Momentary Maintained Mushroom ø40mm Momentary Maintained ➀ Button Color Code Type No.
YW Series Control Units ø22 Pushbuttons with Metal Bezel Style Operation Contact Flush Metal Bezel 1NO 1NC 2NO 2NC 1NO-1NC 3NO 3NC 2NO-1NC 1NO-2NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC Momentary Maintained Extended Metal Bezel Momentary Maintained Mushroom ø40mm Metal Bezel Momentary Maintained ➀ Button Color Code Type No.
ø22 YW Series Control Units Pilot Lights (Unibody Type) Style Illumination Type Flush Full Voltage LED Flush Marking Type Full Voltage LED Extended Full Voltage LED Dome Full Voltage LED Operating Voltage ➁ Lens Color Code Type No.
YW Series Control Units ø22 Pilot Lights (Separate Type) Style Flush Full Voltage Illumination Type Without Lamp LED Type No. ➁ Lens Color Code 250V AC/DC max.
ø22 YW Series Control Units Style Extended Full Voltage Illumination Type Without Lamp LED Operating Voltage 250V AC/DC max. YW1P-2TEQ0➁ 6V AC/DC YW1P-2TEQ2➁ 12V AC/DC YW1P-2TEQ3➁ 24V AC/DC YW1P-2TEQ4➁ 110V AC/DC YW1P-2TEQH➁ 230/240V AC/DC Incandescent Extended Transformer Type Type No.
YW Series Control Units ø22 Dimensions (Separate Type Pilot Lights) • Flush Marking Type Full Voltage Panel Thickness 0.8 to 6 Gasket Locking Ring Panel Thickness 0.8 to 6 M3.5 Terminal Screw Gasket Locking Ring 46.2 9.5 24 24 M3.5 Terminal Screw ø2 9. 8 Full Voltage ø2 9. 8 • Flush 29.6 46.2 Transformer Type 29.6 10 29.6 15.5 29.6 15.5 29.6 Transformer Type Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6 8 9.5 63.3 63.3 29.6 • Dome Full Voltage Panel Thickness 0.
ø22 YW Series Control Units Illuminated Pushbuttons with Plastic Bezel Style Illumination Type Operation Extended Momentary Without Lamp Maintained Momentary LED Maintained Momentary Incandescent Maintained Extended with Full Shroud Momentary Without Lamp Maintained Momentary LED Maintained Momentary Incandescent Maintained Contacts 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO
YW Series Control Units ø22 Style Illumination Type Operation Mushroom ø40mm Momentary Without Lamp Maintained Momentary LED Maintained Momentary Incandescent Maintained Contacts 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC Type No.
ø22 YW Series Control Units Illuminated Pushbuttons with Metal Bezel Style Illumination Type Operation Extended Momentary Without Lamp Maintained Momentary LED Maintained Momentary Incandescent Maintained Extended with Full Shroud Momentary Without Lamp Maintained Momentary LED Maintained Momentary Incandescent Maintained Contacts 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2N
YW Series Control Units ø22 Illumination Type Style Operation ø40mm Mushroom Momentary Without Lamp Maintained Momentary LED Maintained Momentary Incandescent Maintained Contacts 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC 1NO 1NC 2NO 2NC 1NO-1NC ➂ Operating Voltage Code Type No.
ø22 YW Series Control Units Selector Switches with Plastic Bezel Knob Type Style No. of Positions Contact Configuration 1NO (10) 1NC (01) 2NO (20) 2NC (02) 90° 2-Position L R 1NO-1NC (11) 3NO (30) 3NC (03) 2NO-1NC (21) 1NO-2NC (12) No.
YW Series Control Units ø22 Selector Switches with Metal Bezel Knob Type Style No. of Positions Contact Configuration 1NO (10) 1NC (01) 2NO (20) 2NC (02) 90° 2-Position L R 1NO-1NC (11) 3NO (30) 3NC (03) 2NO-1NC (21) 1NO-2NC (12) No.
ø22 YW Series Control Units Contact Block Mounting Position Dimensions • Selector Switch with Plastic Bezel • Selector Switch with Plastic Bezel Contact Block Mounting Position 2 Gasket 3 10 10 1 Panel Thickness: 0.8 to 6 0.5 M3.5 Terminal Screw Contact Block 90° Locking Ring L C R 2-Position Operator Position 11 45.8 24 Lock 45° 41.4 28.6 45° 3-Position 9 ø2 ø2 Kn 7.
YW Series Control Units ø22 Key Selector Switches Operator Position No.
ø22 YW Series Control Units Operator Position No. of Positions Contact Configuration 2NO (20N1) 2NC (02) 2NC (02N1) 1NO-1NC (11) 45° 3-position Maintained L C R 1NO-1NC (11N1) 1NO-1NC (11N2) 1NO-1NC (11N3) 1NO-1NC (11N4) 3NO (30) 3NC (03) 2NO-1NC (21) 1NO-2NC (12) Metal Bezel Contact Block Mounting Position L 2NO (20) Type No.
YW Series Control Units ø22 Operator Position No. of Positions Contact Configuration 2NO (20N1) 2NC (02) 2NC (02N1) 1NO-1NC (11) 45° 3-position Spring Return from Right L C R 1NO-1NC (11N1) 1NO-1NC (11N2) 1NO-1NC (11N3) 1NO-1NC (11N4) 3NO (30) 3NC (03) 2NO-1NC (21) 1NO-2NC (12) Metal Bezel Contact Block Mounting Position L 2NO (20) Type No.
ø22 YW Series Control Units Operator Position No. of Positions Contact Configuration 2NO (20N1) 2NC (02) 2NC (02N1) 1NO-1NC (11) 45° 3-position Spring Return from Left L C R 1NO-1NC (11N1) 1NO-1NC (11N2) 1NO-1NC (11N3) 1NO-1NC (11N4) 3NO (30) 3NC (03) 2NO-1NC (21) 1NO-2NC (12) Metal Bezel Contact Block Mounting Position L 2NO (20) Type No.
YW Series Control Units ø22 Operator Position No. of Positions Contact Configuration 2NO (20N1) 2NC (02) 2NC (02N1) 1NO-1NC (11) 45° 3-position Spring Return Two-way L C R 1NO-1NC (11N1) 1NO-1NC (11N2) 1NO-1NC (11N3) 1NO-1NC (11N4) 3NO (30) 3NC (03) 2NO-1NC (21) 1NO-2NC (12) Metal Bezel Contact Block Mounting Position L 2NO (20) Type No.
ø22 YW Series Control Units Dimensions (Key Selector Switch) • Plastic Bezel • Metal Bezel Panel Thickness 0.8 to 6 Gasket Panel Thickness 0.8 to 6 Gasket M3.5 Terminal Screw Contact Block M3.5 Terminal Screw Contact Block 0.5 0.3 90° 90° Locking Ring Locking Ring 11 11.3 2-position 38 2-position 45° 45° 45° Lock 41.4 28.6 Lock 38 28.6 45° 45.8 41.4 45.8 .5 9.0 ø29 ø2 30.0 3-position 30.0 3-position All dimensions in mm. Accessories Ordering Type No.
YW Series Control Units ø22 Name & Shape Ordering Type No. Padlock Cover Package Quantity Description & Dimensions (mm) Plastic hinged cover to protect pushbuttons, illuminated pushbuttons, or selector switches. Degree of protection: IP65. Applicable panel thickness: 0.8 to 3.2 mm 82.5 Panel Thickness 0.8 to 3.2 93 6.5 R6 1 70 30 HW9Z-KL1 24 0 2 ø2 ø5 .2 Pad Lock Hole ø8 Waterproof Gasket Thickness 0.5 29.
ø22 YW Series Control Units Buttons, Lenses, and Marking Plates Name Style Ordering Type No. ➀➁ Color Code Dimensions (mm) Button (for pushbuttons) Package Quantity 6 3. ø2 Mushroom ø40mm YW9Z-B12➀PN10 YW9Z-B14➀PN10 B: G: R: S: W: Y: black green red blue white yellow 9.3 40 10 ø ø23.6 Extended 6 10.
YW Series Control Units ø22 Nameplates • HWAM, HWAQ, HWAS, and HWAV Type Legend Material Ordering Type No. Type No. Package Quantity Dimensions (mm) Marking Plate HWAM 2.7 14.5 14.9 Plastic (black) 1.5 mm thick 30 Order marking plate separately. HWAM 29 27 1 12.1 HWAM R14.9 HWAMPN10 10 2 ø2 1.5 Marking Plate 29 HWAQ HWAQPN10 10 2.7 14.5 14.9 Plastic (black) 1.5 mm thick 27 30 Order marking plate separately. HWAQ 1 12.1 HWAQ 1 R14.9 ø22 1.9 45 HWAS Plastic (black) 1.
ø22 YW Series Control Units EMO Switch Guards Dimensions (mm) Type No. & Appearance HW9Z-KG3 Dimensions (mm) 35 25 ø2 ø74 52 ø80 ø66 2 ø66.8 2 ø2 38 22 64 47 32 Type No. & Appearance HW9Z-KG1 42 EMO Switch Guard SEMI S2 compliant (Note 1) EMO Switch Guard SEMI S2 compliant (Note 2) HW9Z-KG2 HW9Z-KG4 35 25 2 2. ø2 36.5 ø2 ø90 67 ø75 ø90 ø76.
YW Series Control Units ø22 Safety Precautions • Turn off the power to the YW series control units before starting installation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard. • To avoid burning your hand, use the lamp holder tool when replac- ing lamps. • For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1.0 N·m.
ø22 YW Series Control Units Marking For YW series pilot lights and illuminated pushbuttons, legends and symbols can be engraved on built-in marking plates, or printed mylar film can be inserted under the lens for labeling purposes. Mylar film is not supplied with the control units and must be supplied by the end user. Removing Contact Blocks and Full Voltage Adapter Insert a flat screwdriver between the latch and contact block mounting adapter, and disengage the latch.
YW Series Control Units ø22 Precautions for Noise Nameplate When using the unibody pilot light in an environment where it is subjected to noise, connect a noise suppressor across terminals X1 and X2 as shown below. When anti-rotation is not required, remove the projection from the nameplate using pliers.
ø22 YW Series Control Units 32 (07/12/13)
YW Series Control Units ø22 (07/12/13) 33
Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: marketing@idec.co.jp IDEC CORPORATION (USA) IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD. 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.