Datasheet

60
Maintenance Parts
LB Series Maintenance LED Unit
Package Quantity: 1
Shape
Rated Operating
Voltage
Part No.
(Ordering No.)
* Color Code
LED Unit
5V DC
LB9Z-LED5*
A: Amber
G: Green
PW: Pure White
R: Red
S: Blue
W: White
12V AC/DC
LB9Z-LED1*
24V AC/DC
LB9Z-LED2*
All LB/LBW series contain an LED unit.
• Use a pure white (PW) LED unit for yellow (Y) illumination.
LB/LBW Series Maintenance Parts
Package Quantity: 1
Transformer Primary Voltage Secondary Voltage
Part No.
(Ordering No.)
Applicable Load
For 24V
AC100/110V 100/110V AC ±10% TWR512
LB9Z-LED2*
(24V AC/DC LED unit)
AC200/220V 200/220V AC ±10% TWR522
AC400/440V 400/440V AC±10% TWR542
Terminal cover (TWR-VL3) is supplied as standard.
Connect one LB9Z-LED2* to a transformer.
Accessories
35mm DIN Rail
Part No. Ordering No. Length Material Package Quantity
BAA1000 BAA1000PN10 1,000mm Aluminum (approx. 200g) 10
BAP1000 BAP1000PN10 1,000mm Steel (approx. 320g) 10
End Clip
Part No. Ordering No. Applicable DIN Rail Package Quantity Dimensions
BNL6 BNL6PN10
BAA1000
BAP1000
10
Approx. 15g
Steel (Zinc-
plated)
BC9Z-E/NS35N
BC9Z-E/NS35NPN10
BAA1000
BAP1000
10
Approx. 15g
45
9
(24)
32.8
48.6
9.5
Transformer
Specifications
Part No.
TWR52
Operating Voltage
100/110V AC, 200/220V AC, 400/440V AC (50/60Hz)
Current Draw 2.4VA
Rated Insulation Voltage 600V
Insulation Resistance 100 MΩ minimum (500V DC megger)
Operating Temperature –30 to +60°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Operating Humidity 35 to 85% RH (no condensation)
Vibration Resistance
Damage Limits: 30 Hz, amplitude 1.5 mm
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Shock Resistance
Damage limits: 1,000 m/s
2
Operating Extremes: 100 m/s
2
Dielectric Strength 2,500V AC, 1 minute
Terminal Screw M3.5
Applicable Wire 2 mm
2
maximum, 2 wires maximum
Weight (approx.) 87g
45.5
52
41
40
48
40
22
30
BAA1000
1
3 4
JAPAN
2
PRI.
SEC.
M3.5
Terminal Screw
Terminal Cover
Secondary Side Primary Side
2-ø3.3
Mounting Hole
5
All dimensions in mm.
Dimensions