RV8H Interface Relays Slim, space-saving interface relays.
Ultra-slim interface relays Suitable for high density mounting • Screw and spring clamp terminals • Release lever for easy locking and removal of relay • Green LED indicator • 6A contact capacity in the slim housing • Gold-plated contacts for high contact reliability • Minimum applicable load: 6V DC, 10mA • 12 coil voltage types to meet various needs 70 Marking plate can be installed on the release lever.
RV8H Interface Relays Space-saving 6mm width suitable for high density mounting. • Screw and spring clamp terminals available • Release lever for easy locking and removal of relay • Green LED indicator • 6A contact capacity in a slim housing • Gold-plated contacts for high contact reliability • Wide input voltage range: 6 to 240V • Marking plate can be installed on the release lever Applicable Standards Mark UL508 CSA C22.2 No. 14 Certification Organization / File No. UL listed, File No. E55996 VDE No.
RV8H Interface Relays Marking Plate Shape Package Quantity: 1 Part No.
RV8H Interface Relays Contact Ratings Allowable Contact Power Resistive Load Inductive Load 1,500VA AC 180W DC B300/R300 (pilot duty) Rated Load Voltage Resistive Load 250V AC 30V DC 6A 6A Inductive Load Allowable Switching Current Allowable Switching Voltage Minimum Applicable Load 6A 400V AC 125V DC 6V DC, 10 mA (reference value) B300/R300 (pilot duty) Coil Ratings Coil Voltage Code Rated Voltage (V) DC AC/ DC 6V DC 9V DC 12V DC 18V DC 24V DC 12V AC/DC 18V AC/DC 24V AC/DC 48V AC/DC 60V A
RV8H Interface Relays Dimensions All dimensions in mm. 74.2 74.2 35 88 69.6 Spring Clamp Terminal RV8H-S 69.6 Screw Terminal RV8H-L 35 93.4 6.1 Jumper SV9Z-J20*PN10 6.1 DIN Rail Spacer SV9Z-SA2W 115.9 66.8 2.8 71.4 6 120 12.3 6.1 Marking Plate SV9Z-PW10 Cut 3 10.5 16.5 35 1 2 96.7 6 86.