Photoelectric Switch with Built-in Power Supply
SA1U Series
Universal VoltageDC Power Types/With or Without Time-delay Outputs
DC Power Type
SA1U-T50MW (T)
SA1U-P07MW (T)
SA1U-D01MW (T)
SA1U-B02MW (T)
Detection Mode
Through-beam
Polarized Retro-reflective
Diffuse-reflective
Background Suppression
Universal Voltage Type
SA1U-T50M (T)
SA1U-P07M (T)
SA1U-D01M (T)
SA1U-B02M (T)
Caution notices are used where inattention might cause personal injury or damage to
equipment.
Type No. and the wiring diagram, are indicated on the housing and the cover.
When installing the cover, confirm that the cover type the agrees with the housing.
1
Type
2
Dimensions (mm)
3
Installation
Tighten all screws surely to maintain the water-proof
characteristics. (Except for UL / c-UL)
Excessive tightening causes damage. Tighten the
screws within the tightening torque range shown at
right.
Screw
Terminal
Gland
Cover Screw
Mounting Screw
Tightening Torque
0.6 to 1.0
4.0 to 6.0
0.5 to 0.8
0.8 to 1.2
Screw Tightening Torque (Nm)
4
Specifications
Universal
Voltage
DC
Power
Sensing Range
Detectable Object
Hysteresis
Light Source Eiement
Extraneous Light immunity
Temperature Range
Operating Humidity
Degree of Protection
Power Voltage
Power Consumption
Output
Response Time
Power Voltage
Power Consumption
Configuration
Resistive Load
Output Voltage
Voltage Drop
Response Time
Through-beam
SA1U-T50M
SA1U-T50MT
SA1U-T50MW
SA1U-T50MWT
50m
Opaque
-
Infrared LED
Sunlight 10000lx maximum, Incandescent lamp 5000lx maximum
-25 to 60 (no freezing), Storage temperature: -40 to 70 (no freezing)
35 to 85% RH (storage temperature)
IP67 (IEC/EN60529) NEMA TYPE 1 (For UL / c-UL)
24 to 240V AC (21.6 to 264V AC) 50/60Hz, 12 to 240V DC (10.8 to 264V DC)
Projector: 3 VA maximum
Receiver: 3 VA maximum
Electromechanical SPDT, Swithing capacity: 250V AC3A (resistive load), 30V DC3A (resistive load)
20ms maximum
12 to 24V DC, Ripple p-p 10% maximum (10 to 30V DC)
Projector: 20 mA maximum
Reciever: 25 mA maximum
NPN and PNP transistor open collector
100 mA maximum
30V DC maximum
2.4V maximum
1 ms maximum
Polarizedb Retro-reflective
SA1U-P07M
SA1U-P07MT
SA1U-P07MW
SA1U-P07MWT
0.2 to 7m (Using the attached reflector)
Opaque/Specular
-
Infrared LED
3 VA maximum
30 mA maximum
Diffuse-reflective
SA1U-D01M
SA1U-D01MT
SA1U-D01MW
SA1U-D01MWT
1m (200 × 200mm white mat paper)
Opaque/Specular
20% maximum of operation distance
Infrared LED
Background Suppression
SA1U-B02M
SA1U-B02MT
SA1U-B02MW
SA1U-B02MWT
0.2 to 2m (200 × 200mm white mat paper)
Opaque
15% maximum of operation distance
Sensing Method
5
Notes for Operation
Prevent incidence of reflected light from the floor or wall.
Do not expose the photoelectric switch to sunlight or other direct light projections.
Do not strike the photoelectric switch with a hammer when instlalling, otherwise the waterproof
characteristics will be impaired. (Except for UL / c-UL)
For preventing the transient state when turning power on, a circuit to turn output off (universal
voltage: 200 ms, DC power: 50 ms) is contained. On the timer-function model, time-delay
operation starts when the output is released from the off state. Take care of the operation when
turning power on.
Do not use the photoelectric switch under conditions exceeding the rated operating
temperature, vibration resistance, and shock resistance.
Use the photoelectric switch within the rated power voltage.
When using a switching power supply, connect the FG (frame ground) terminal to a proper
ground.
When compliance with the EU Low Voltage Directive is required, connect an EN approved fuse
outside the power terminals of the universal voltage type.
Install the cover maintain the water-proof characteristics, install the cover in a regulated
position.
6
Wiring Diagram
Connect wires starting from the lower terminals.
Install the cover using the captire screw.
Use a cable of 8 to 10 mm in diameter to ensure water- and dust-proof characteristics(Except
for UL / c-UL). Two gland packings are supplied; for cables of 8 to 9 mm and 9 to 10 mm in
diameter. Use a proper gland packing and a gland washer, and tighten the gland firmly. Keep
the cable insulation within 5 mm from the gland packing as shown above. Make sure that the
gland washer is placed in the gland packing correctly.
Turn off the power supply before wiring.
Connect correctly to prevent damage.
The power voltage must not exceed the rated range.
The cable should not be run in the same wire duct with other power supply, motor, or
electromagnetic lines because induction noise will cause malfunction or damage to the
photoelectric switch.
Cable extension is allowed up to 100m using a cabtyre cable with core wires of 0.3 mm
2
or
more. On the DC power supply type, consider the voltage drop by the resistance of the cable.
Cable Connection
Specifications
Universal Voltage
Type
DC Power Type
Universal
Voltage
Power
Suplly
Circuit
NO
COM
NC
Terminal No.
Terminal No.
Power Voltage
24 to 240V AC
50/60Hz
or
24 to 240V DC
Relay Contact
(SPDT)
Sensing Circuit
Universal Voltage
Power Supply Circuit
Sensing
Circuit
PNP
V
OUT
NPN
0V 12 to 24V DC
12 to 24V DC
OUT
Terminal No.
Load
Load
Internal Circuit External Wiring
Internal Circuit External Wiring
1
2
1
5
4
3
2
1
1
3
4
2
2
Other than the through-beam
type projector
Universal Voltage Type DC Power Type
Other than the through-beam
type projector
Through-beam type projector Through-beam type projector
Power Voltage
24 to 240V AC
50/60Hz
or
24 to 240V DC
Applicable Lead Extension
Terminal No.
A (mm)
45
30
55
40
25
Output
7
Optical Axis Alignment & Sensitivity Adjustment
(1) Through Beam Type
Direct the projector and the receiver face by eye measure and fasten them tentatively. Direct
the receiver upward, downward, and sideways and lock the projector in the middle where the
indicator on the receiver goes on.
(2) Polarized retro-reflective
Direct the sensor upward, downward, and sideways and lock the reflector in the middle
where the indicator goes on or off.
(3) Diffuse-reflective
Place the sensing object and direct the sensor upward, downward, and sideways and lock
the reflector in the middle where the indicator goes on or off. Without the sensing objects in
place, check the indicator goes off. If the background influences, make the sensitivity
adjustment as follows.
(a) With the sensing object in place, turn the sencitivity adjusting control clock wise from MIN
position until the indicator goes on (point A).
(b) Remove the object, then the indicator will go off. Turn the sensitivity adjusting control further
clockwise until the indicator goes on again by detecting the background (Point B).
(c) Set the sensitivity adjusting control at Point C, the middle point between A and B. This point
gives the best sensitivity.
NOTE: Use the attached screwdriver to make adjustments. Avoid excessive force to the
sensitivity adjusting control to prevent damage.
(4) Make the sensitivity adjustment of the background suppression (BGS) as follows.
(At dark on operation, read lighting the operation indicator in a different way as turning off
and adjust it.)
First, direct the sensor and place the object, turn the sensitivity adjusting control
counterclockwise until the indicator goes off. Then turn the sensitivity adjusting control
clockwise until the indicator goes on (Point A).
Remove the object, then the indicator will go off. Turn the sensitivity asjusting control further
clockwise until the indicator goes on again by detecting the background (Point B) (*1).
Set the sensitivity adjusting control at Point C, the middle point between A and B (*2).
*1: Make one turn or more clockwise from point A and set the position as point C when the
background is too far and the operation LED dose turn on.
*2: There may be more than 1 turn between points points A and B, since this photelectric
switch incorporates a 6-turn adjuster.
8
Operation Chart
OFF-delay
Normal
One-shot
ON-delay
OFF-delay
Normal
One-shot
ON-delay
Normal
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Light ON Dark ON
Operation Mode
Incident
Interrupt
T T
T T
T T T
T T
T T T
T T
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Type No.
Without Time-delay
With Time-delay
Without Time-delay
With Time-delay
φ 3.2 min.
6.0 max. 6.0 max.
5.2 min.
11.0 max.
3.3 max.
φ 3.2 min.
6.0 max. 6.0 max.
5.2 min.
11.0 max.
3.3 max.
Applicable Crimping Terminal Dimensions
(mm)
Ring
Spade
When connecting crimping terminals, note the direction of the crimping part as shown.
Gland
Gland Washer
Gland Packing
(Two gland packings
in different sizes are supplied.)
φ8 to 10 mm
Approx. 5 mm A
When using crimping terminals, wrap the terminal with insulating tubes.
Each screw terminal can accept only one crimping terminal.
Sensing Circuit
Sensing Circuit
Internal Circuit External WiringInternal Circuit External Wiring
Light ON
Incorrent
SA1U- □□□□
Sensing Method
T: Through-beam (Infrared LED)
P: Polarized retro-reflective
D: Diffuse-reflective
B: Back ground suppression (BGS)
Power supply type
blank: Universal voltage
W: DC
Time-delay
blank: Without
T: With
Sensing Range
50M: 50m
07M: 7m
01M: 1m
02M: 2m
10
5
10
40
25
30
22
40
50
557
5.5
67.5
85
190
P, D: Receiver
P: Projector
T: Projector or
receiver
D: Projector
10.5
B: Projector
Time-delay Control
(With Time-delay)
Mode Selector
Without Time-delay: L/D-on
With Time-delay: Timer Mode,
       L/D-on
Operation LED (Yellow)
Stable LED (Green)
(T, P, D Type)
Distance Control
(B type)
Sensitivity Adjustment
(T, P, D Type)
Joint
Terminal screws
(There are five
places or less.)
Mounting screws
(Two places)
Gland
Install the cover without leaving a gap at
the joint.