User Guide

Error
number
Details Possiblereason Solutionsuggestion
12.InstructionsforusingSE2Lforthe
firsttimeafterpurchase
SE2L does not operate withoutinitial configuration. Install and
useSLSProject Designer from CD provided with the product to
configureSE2L.
(1)SLSUSBdriverinstallation
a) ConnecttheSE2Lto PC'sUSB port. PC will detect the new
hardwareandopenthe“FoundNewHardwareWizard”.
b)Select“Installfromalistorspecificlocation(Advanced)”,insert
theCDthenclick[Next>].
c)Select“Searchforthebestdriverintheselocations”.Thenselect
“Includethislocationinthesearch”,andclick[Browse].
d)Selectthe“Driver”folder,thenclick[OK].
e)Click [Next>]. The wizardstarts searching for thedriver and
dialogueboxisshown.
f)WindowsstartsinstallingtheSLSUSBdriver.
g) After clicking [Finish], the dialogueappears indicating new
hardwareissuccessfullyinstalled.
Toconfirm that theSLSUSBdriver was successfullyinstalled, goto
thecomputer'sdevicemanagerandexpand the“Ports(COMandLPT)”list,
“SLSUSBDeviceDriver”shouldbeseenasoneoftheCOMports.
(2)SLSProjectDesignerinstallation
a)InserttheCDintotheCD-ROMdrive.
b) Click“ SLSProjectDesigner*.*installer.exe”.
c) Follow the instructions of the installer and complete the
installation.
(3)ConfigurationProcedure
a)RuntheinstalledSLSConfiguratorsoftware.
b)Followingapplication window will appear. Select[Createnew
configuration]andclick[OK]button.
c)Followingconfigurationwindowwillappear.Click[Connections]→
[Connect]fromthemenu.
d)Followingpassworddialogboxwillappear.Enterdefaultpassword
[12345678]andclick[OK].
e) Following configurationwindow willappear. A message box
[Deviceconfigurationisincomplete!Pleasereconfigurethedevice]
willappear,refertoChapter7oftheuser'smanualandcomplete
thefunctionconifguration,andwriteintotheSE2L.
Configurationiscompleted.
Color Signal
Function
Description
AWG
Yellow/
Green
RESET
1
Input Resetinput1 28
Yellow/
Blue
RESET
2
Input Resetinput2 28
Orange
RESREQ1/
MUTOUT1
Output
RESREQ1:Requestoutput1
MUTOUT1:Mutingstateoutput1
28
Orange/
Black
RESREQ1/
MUTOUT2
Output
RESREQ2:Requestoutput2
MUTOUT2:Mutingstateoutput2
28
White/
Blue
(TP)
RS-485
Communic
ation
CommunicationprotocolRS-485 28
White/
Red
(TP)
RS-485
Communic
ation
CommunicationprotocolRS-485 28
Shield
wire
FG
Frameground
(5)Input/Outputcircuit
●
OSSD/WarningOutputcircuit
OSSD/WarningoutputsareNchannelMOSFETtype.
OSSD1
OSSD2
Control
circuit
+24V
OSSD4/WARNING2
OSSD3/WARNING1
Fig-16.OSSD/WARNINGOutputcircuit
●
Otheroutputcircuits
RESREQ1,RESREQ2,MUTOUT1,MUTOUT2outputsarePNPtype.
RESREQ1/MUTOUT1
Control
circuit
+24V
RESREQ1/MUTOUT2
Fig-17.Outputcircuit
●
Inputcircuit
Figure 18 shows input circuit for Area input, EDM1, EDM2,
RESET1,RESET2,MUTING 1,MUTING2,MUTING3, MUTING4,
OVERRIDE1,andOVERRIDE2signals.
Fig-18.Inputcircuit
11.Troubleshooting
(1)Troubleshooting
Situation Possiblereason Solutionsuggestion
SE2Lisnot
operating
Powersupplyis
OFF/Overvoltage
Undervoltage
MakesurepowersupplyisON
Checkthesupplyvoltage
Checktheconditionofthepowersupplycable
Cableisdamaged Replacewithanewcable
Configurationis
incomplete
ReconfigureSE2L
SE2Lisnot
connected
withthe
SLSProject
Designer
PCtrouble
CheckthePCʼsspecication.Makesurethe
specificationiscompatible
Closetheotherunrelatedapplicationsandreconnect
PowersupplyisOFF
MakesurethepowersupplyisON
Checkthesupplyvoltage
Checktheconditionofthepowersupplycable
USBcableisnot
connectedtoUSB
port
MakesuretheUSBisconnectedtobothPCand
SE2L
Situation Possiblereason Solutionsuggestion
Measurement
dataisnot
displayed
PowersupplyisOFF MakesurethepowersupplyisON
SE2Lisinerror/
lockoutstate
Checkthesupplyvoltage
Checktheconditionofthepowersupplycable
Checktheerrornumberinthe7-segmenttable
RestartSE2Lifitisblinking
OSSDremain
OFFeven
thoughthe
protection
zoneisfree
fromobstacle
Lightinterference
MountSE2Latalocationfreefromlightinterference
Refertosection6forlightinterferencecounter
measures
Mutualinterference
Refertosection7formutualinterferencecounter
measures
Contaminatedoptical
window
Checkforanycontaminationordamageontheoptical
window
Floorisdetected
Makesurefloorisnotdetected
Reconfigurethedetectionarea
Backgroundis
detected
Makesurethatthebackgroundisnotinsidethe
detectionarea.Reconfigurethedetectionarea
Lockoutstatedueto
self-diagnosticfunction
Checkthedescriptionoftheerrornumberand
performthepossiblesolutionassuggested
SE2Lisinterlocked
Checktheconfigurationoftheinterlockfunction.If
RESETisON,supplySE2LwithRESETsignal
(2)Errornumberlist
Table4showstheerrornumberoftheSE2L.Theseerrornumbers'
information is displayedonthe7-segment display of theSE2L. If
theSE2Lisunabletoresumenormaloperation,pleasecontactthe
nearestdistributororsalesrepresentativeforsupport.
Table-4.Errornumberlist
Error
number
Details Possiblereason Solutionsuggestion
45
Settingerror/
Incompletesetting
ReconfigureSE2L
Automaticrecovery
orInputreset(During
Interlocksetting)
56 Invalidareaerror
Confirmtheinputstatus
duringareaswitching
Automaticrecovery
orInputreset(During
Interlocksetting)
57
AreaInputConnection
Error
Confirmtheinputstatus
duringareaswitching
Automaticrecovery
orInputreset(During
Interlocksetting)
59 Areasequenceerror
Confirmareaswitching
sequence
Automaticrecovery
orInputreset(During
Interlocksetting)
5B
5D
5F
Encoderspeederror
Makesuretheencoder
speediscorrectlyconfigured
Automaticrecovery
orInputreset(During
Interlocksetting)
5C Encodererror
Confirmtheencoderinput
status
Automaticrecovery
orInputreset(During
Interlocksetting)
5E
Invalidareaerror
(DuringEncoderisvalid)
Confirmtheinputstatus
duringareaswitching
Automaticrecovery
orInputreset(During
Interlocksetting)
60
63
Motorerror
Mountthesensorinaway
thatthevibration,bump
statedinthespecification
doesnotexceed
Automaticrecovery
orInputreset(During
Interlocksetting)
64
Master/Slave
communicationerror
Confirmtheconnection
betweenmasterandslave
Automaticrecovery
orInputreset(During
Interlocksetting)
70
Opticalinterference/
Highreflective
background
MountSE2Latalocationfree
fromlightinterference.Referto
section6forlightinterference
countermeasures
Automaticrecovery
orInputreset(During
Interlocksetting)
72
Operatingtemperature
error
Makesurethatoperating
temperatureiswithin
specification.
Restartthepowersupply
74
79
Powersupplyerror
Makesurethatvoltageiswithin
thespecification
Restartthepowersupply
7C
OSSDexcesscurrent
error
MakesuretheOSSDloadis
withinthespecification
Restartthepowersupply
7D Slaveunit1error
Checktheerrorcodeon
slaveunit1
Automaticrecovery
orInputreset(During
Interlocksetting)
7E Slaveunit2error
Checktheerrorcodeon
slaveunit2
Automaticrecovery
orInputreset(During
Interlocksetting)
7F Slaveunit3error
Checktheerrorcodeon
slaveunit3
Automaticrecovery
orInputreset(During
Interlocksetting)
Input
0V
Control
circuit
84
85
B1
C0
Objectinlimiteddetection
zoneorcontaminationon
theopticalwindow
Cleantheopticalwindow(referto
chapter8.5ofthemanual).Further,
removeanyobjectspresentinside
thezonewithlimiteddetection
capability(refertochapter5.4)of
SE2L.
Automaticrecovery
orInputreset(During
Interlocksetting)
86
Mutualinterference
error
MountSE2Latalocationfree
frommutualinterference.
Refertosection7mutual
interferenceforcounter
measures
Automaticrecovery
orInputreset(During
Interlocksetting)
8F
SDcarddetectionerror
CheckSDcardfileorcheck
thespecificationoftheSD
card
Automaticrecovery
orInputreset(During
Interlocksetting)
95
9A
OSSDdiagnosticerror
ChecktheOSSDoutputwire Restartthepowersupply
A6
EDM1inputconnection
error
ChecktheEDM1inputwire Restartthepowersupply
A7
EDM2inputconnection
error
ChecktheEDM2inputwire Restartthepowersupply
A9 Resetinputerror ChecktheRESETinputwire Restartthepowersupply
AA
Referencemonitorerror
Checkforthedisplacement
ofreferencestructureor
SE2Lposition
Automaticrecovery
orInputreset(During
Interlocksetting)
C1
Opticalwindow
isremovedor
contaminated
Replaceorcleantheoptical
window
Restartthepowersupply
CE
Adjustmentoftheoptical
windowisincompleteafter
replacement
Adjusttheopticalwindow
Automaticrecovery
orInputreset(During
Interlocksetting)
CF SE2LisnotconfiguredConfigureSE2L
Automaticrecovery
orInputreset(During
Interlocksetting)
D3
E6
Configurationis
incomplete
ReconfigureSE2L
Automaticrecovery
orInputreset(During
Interlocksetting)
F0
SDcardinitialization
error
Removethecardandtry
again
Automaticrecovery
orInputreset(During
Interlocksetting)
F1
SDcardfilecontent
error
Checkthesettingfileinthe
SDcard
Automaticrecovery
orInputreset(During
Interlocksetting)
Error
other
than
(40
F5)
DeviceError
MakesurethatFGwireis
correctlytotheground.
Alsocheckthesurrounding
disturbanceoftheoperating
environment.
Mountthesensorwithinthe
statedvibration,bumpinthe
specification.
ReplaceSE2Lifitdoesnot
recoverevenafterrestoring
thepowersupply.Contactthe
nearestdistributororsales
representativefortherepair.
Restartthepowersupply
※In7segmentdisplayBandDwilldisplayasbandd.
A8,AC
80 Masteruniterror
Checktheerrorcodeon
masterunit
Automaticrecovery
orInputreset(During
Interlocksetting)